___________________________________________________________
CXR Larus 80-100-400 Issue 2 July 2006 page
3-34
T1 type (54511) or CC/5 MHz/10MHz (54513-3, -4, -5).
E
Displayed momentarily immediately after power-up if input card is
E1 type (54512-2).
NOTE:
For the clock card to detect an E1 type of input card, the input card itself must be
present. Without an E1 input card physically plugged in, the clock card will default to run
the T1 type of operation.
E, then 2
Displayed momentarily immediately after power-up if clock card
detects a 2.048 MHz square wave input card (54512-1).
g
Displayed when unit has successfully entered GPS in Known
mode. This is the
normal
steady-state indication. (Not to be
confused with DS1/E1 error condition ’9'.) The lower case ‘g’ letter
has a “tail” segment that is not present on the digit ‘9’.
g.
Displayed when unit has entered GPS in Position Average mode.
This is the
non
steady-state indication.
L
Acquiring input reference.
H HOLD
state.*
A
Synthesizer control in top 25% of range.
b
Synthesizer control in bottom 25% of range.
=
Primary input in use.*
||
Secondary input in use.*
c
Standalone state: Internal switch S2 in TEST position.
r
Free running state: No input is present and no tracking has
occurred. Happens on power-up if TEST pushbutton is not being
pressed and no good DS1/E1 inputs are present.
b. Error conditions when card goes into HOLD state*:
2
Excess BPVs; does not cause hold.
3 LOF
synchronization.
4 AIS.
5
Input in Yellow Alarm state.
6
Excessive frame bit errors (FBEs); does not cause hold.
7
Outside nominal cyclic tracking range of ±7.1 Hz or jitter more than
7 UI peak.