CXR Larus 80-100-400
Issue 1, July 2006
____________________________________________________________
_____________________________________________
page
4-7
Table 4-A
StarClock 200E Alarm Thresholds (Sheet 1 of 2)
54511/54512 Input Card
Excess bipolar violations (BPVs), error ratio approximately 10
-4
54522 and 54523 Track and Hold Clock Cards
Alarm
Default Threshold
Other Settable
Threshold
Frame Bit Errors (FBEs)
Two per second
-
Cyclic redundancy
checking (CRC) errors
16 in 10 seconds
0 to 65,535 per interval*
BPV errors
16 in 10 seconds
Same
54541/54542 Synchronization Monitor Card
Alarm
Default Threshold
Other Settable
Threshold
Loss of Signal (LOS)
From T1/E1 receiver
-
Out of Frame (OOF)
Loss of frame (LOF)
synchronization for
100 milliseconds
-
BPV
16 in 10 seconds
0 to 65,535 per interval*
Invalid CRCs
Same as BPV above
Same
Time Interval Error (TIE)
1.59 unit interval (UI) for
T1, 2.17 UIs for E1, 1033
ns for T1/E1 in 1 hour
(Stratum 2, 3E)
0 to 65,535 per interval*
Maximum Time Interval
Error (MTIE)
Same as TIE above
Same
Slip
5 frame slips for T1, 1
frame slip for E1 in 1 hour
0 to 99 slips per interval*
Jitter
5 UIs for T1, 1 UI for E1
peak-to-peak over
1 second
-
*
Threshold intervals available are 1 second, 10 seconds, 1 hour, and 1 day.