___________________________________________________________
CXR Larus 80-100-400 Issue 2 July 2006 page
3-2
3.22 Environmental
Limitations
3.221 Operating
Temperature:
0
°
C to 45
°
C
The 54522, 54523, 54591, and 54593 Track and Hold Clock Cards operate at
any ambient temperature within this range; however, their performance to
specification requires two additional temperature restrictions:
a. The ambient air temperature surrounding the track and hold cards must be
controlled to ±5
°
C with respect to the normal or average ambient
temperature. That is, the ambient temperature may reside within 0
°
C to
45
°
C, but the variance in temperature must be held to a 5
°
C deviation for
the duration of the measurement in order to guarantee the clock
specifications.
b. The slew rate of ambient temperature change, within the 5
°
C deviation
limit, must be limited to 8
°
C per hour.
3.222 Storage
Temperature:
-40
°
C to 70
°
C
3.223 Humidity:
Operating 0% to 95%, noncondensing at 40
°
C
Storage
Up to 95% RH
3.224 Shelf Dimensions (master or expansion):
Width
19.00" (48.2 cm)
Depth
12.10" (30.7 cm)
Height 12.25" (31.1 cm)
3.225 Weight:
28 lbs (12.6 kg) maximum per shelf, fully loaded