6-6
Compaq Deskpro Workstation AP250 Maintenance and Service Guide
Compaq Confidential – Need to Know Required
Writer: Bruce Sullivan Project: Compaq Deskpro Workstation AP250 Maintenance and Service Guide Comments:
Part Number: 118133-001 File Name: g-ch6 Jumper and Switch Information.doc Last Saved On: 10/4/99 10:08 AM
Ultra3 SCSI Hard Drive (18.2-GB WU3 10,000 rpm)
Printed
Circuit
Board
Pin 1
J2
SCSI ID
0
1
2
3
4
5
6
Bit 0
Bit 1
Bit 2
Jumper NOT Installed
Jumper Installed
SCSI ID Settings
Key
18-GB
Drive Size:
Ultra3 SCSI
Model:
J2
Default Settings
Jumper NOT Installed
Jumper Installed
Key
Signal
S
P
W
X
Description
Start Unit Command Enabled
Parity Enabled
Write Protect Disabled
Synch Data Transfer Enabled
Jumper
n/a
Pin 1
J2
Bit 2
Bit 0
Bit 3
Bit 1
S
P
SCSI
POWER
Pin 1
J1B
1. All jumper and switch settings are shown in the
factory default setting, including those not labeled.
2. Termination is disabled/removed.
NOTES:
n/a
This drive is intended for non-pluggable
applications only. Migration to a
Hot-Pluggable Drive Tray is not supported.
NOTE:
Figure 6-5. Locating the jumper positions for the Ultra3 SCSI hard drive