
ID-FLX Lite Global Guide
67
Input
Analog input
CU: AI1-AI9
AIO: AI1-AI4
Binary input
Binary input
LoadRequest2
LoadRegDisable
(optional)
Binary input
Binary input
RegRequest2
R Reg Disable
(optional)
Output
Analog output
Analog output
Load Limit
ByRPMCtrlAout
(plug-in module)
Setpoints
Load limit
Load Input = Load
Load Bias
Load Request 1
Load Request 2
Load ReqRamp
Load UpLimit
Load DownLimit
Load Gain
Load Integral
Regulator
Reg Input
Reg Bias
Request
Request 2
Reg Gain
Reg Integral
Engine load limitation with analog output
Purpose: Protect the engine against overload by reducing the load.
Description: The engine load (e.g. feeder speed) is reduced when actual “Percentual load” (coming from ECU) is
over the
(or
) setpoint. Load can be continuously
Summary of Contents for InteliDrive FLX LITE
Page 19: ...ID FLX Lite Global Guide 19 4 3 Terminal diagram and dimension ...
Page 21: ...ID FLX Lite Global Guide 21 Example Default analog output curves ...
Page 22: ...ID FLX Lite Global Guide 22 Example Wiring for Dacon gauges and IL NT AOUT8 ...
Page 44: ...ID FLX Lite Global Guide 44 5 2 Binary inputs and outputs ...
Page 57: ...ID FLX Lite Global Guide 57 5 14 Display screens and pages structure ...
Page 83: ...ID FLX Lite Global Guide 83 7 Communication 6 back to Table of contents ...