Status and Statistics
Health and Power
Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x
50
4
-
Failure
—Regular fans failed and redundant fan is not operating correctly.
•
Temperature
—The options are:
-
OK
—The temperature is below the warning threshold.
-
Warning
—The temperature is between the warning threshold to the critical
threshold.
-
Critical
—Temperature is above the critical threshold.
-
N/A
—Not relevant.
Power Supply Status
(these fields are found on device that are PD devices and in devices that
support RPS)
•
Power Supply Status
—The options are:
-
Main
—Displays one of the following:
Active—Power supply is being used.
Failure—Main power has failed.
-
Redundant
—Provides the status of the redundant power supply. Displays one of
the following:
Active—Redundant Power Supply (RPS) supply is being used.
Available—RPS is connected but is not being used.
Not Available—RPS is connected but is already providing power to other
devices.
Not Connected—The RPS is not connected.
Present—The RPS is connected.
Ethernet Power Supply Table (displayed only if one of the units in the stack supports PD
ports). The following fields are displayed:
•
Port Name
—Number of port.
•
PD Status
—Displays one of the following values:
-
Connected
—The PD port is connected to a PSE device that is providing power.
-
Not Connected
—The PD port is not connected to a PSE device.
•
Negotiation Mode
—One of the following values.
-
Auto
—CDP or LLDP negotiation is used to determine power level.