Status and Statistics
Health and Power
Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x
48
4
•
PoE
—The
Port Management > PoE > Settings
page is displayed. Connect the time
range to the PoE operations on one or more ports.
If the device is not part of a stack, the Health and Power page displays the following
fields:
Health Table
•
Fan Status
—The following values are possible:
-
OK
—Fan is operating normally.
-
Failure
—More than one fan is not operating correctly.
-
N/A
—Fan is not applicable for the specific model.
•
Redundant Fan Status
—The following values are possible:
-
Ready
—Redundant fan is operational but not required.
-
Active
—One of the main fans is not working and this fan is replacing it.
•
Temperature
—The options are:
-
OK
—The temperature is below the warning threshold.
-
Warning
—The temperature is between the warning threshold to the critical
threshold.
-
Critical
—Temperature is above the critical threshold.
-
N/A
—Not relevant.
Main Power Status
(these fields are found on device that are PD devices and in
devices that support RPS)
-
Main Power Supply Status
—Displays one of the following for the main power
supply:
Active
—Power supply is being used.
Failure
—Main power has failed.
-
Main Power Supply Budget
—Amount of power that can be can be allocated for
device PSE operation by the main power supply.