2-26
Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switch System Message Guide
OL-9641-04
Chapter 2 Messages and Recovery Procedures
GBIC_SECURITY Messages
Error Message
GBIC_SECURITY-4-EEPROM_CRC_ERR: EEPROM checksum error for GBIC in
[chars].
Explanation
This message means that the GBIC in the specified port has invalid EEPROM data.
[chars] is the port in which the GBIC is inserted.
Recommended Action
Remove the GBIC from the port.
Error Message
GBIC_SECURITY-4-EEPROM_READ_ERR: Error in reading GBIC serial ID in
[chars].
Explanation
This message means that an error occurred while the switch was reading the GBIC type
from the EEPROM. [chars] is the port in which the GBIC is inserted.
Recommended Action
Remove the GBIC from the port.
Error Message
GBIC_SECURITY-4-EEPROM_SECURITY_ERR: GBIC in [chars] failed security
check.
Explanation
The GBIC in the specified port has invalid EEPROM data. [chars] is the port in which
the GBIC is inserted.
Recommended Action
Remove the GBIC from the port.
Error Message
GBIC_SECURITY-4-GBIC_INTERR: Internal error occurred in setup for GBIC
interface [chars].
Explanation
This message means that the system could not allocate resources or had some other
problem during the setup for the specified SFP module interface. [chars] is the interface in which
the SFP module is installed.
Recommended Action
Reload the switch by using the
reload
privileged EXEC command. If the
problem persists, find out more about the error by using the
show tech-support
privileged EXEC
command and by copying the error message exactly as it appears on the console or system log and
entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For
more information about these online tools and about contacting Cisco, see the
“Error Message
Traceback Reports” section on page 1-3
.
Error Message
GBIC_SECURITY-6-SFP_INSERTED: Transceiver SFP [chars] module inserted
in [chars]
Explanation
The online insertion and removal (OIR) facility detected a newly inserted transceiver
module for the interface specified in the message. The first [chars] is the module and the second
[chars] is the interface.
Recommended Action
No action is required.