Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switch System Message Guide
OL-9641-04
Chapter 2 Messages and Recovery Procedures
BACKUP_INTERFACE Messages
Error Message
ACLMGR-3-UNLOADING: Unloading [chars] label [dec] feature.
Explanation
This message means that the ACL manager was unable to fit the complete configuration
into the hardware, so some features will be applied in software. This prevents some or all of the
packets in a VLAN from being forwarded in hardware and requires them to be forwarded by the
CPU. Multicast packets might be dropped entirely instead of being forwarded. [chars] is the
direction (
input
or
output
), and [dec] is the label number.
Recommended Action
Use a simpler configuration. Use the same ACLs on multiple interfaces, if
possible.
BACKUP_INTERFACE Messages
This section contains the Flex Link message.
Error Message
BACKUP_INTERFACE-5-VLB_NON_TRUNK: Warning: Flexlink VLB is not
allowed on non-trunk ports. Please configure [chars] to be a trunk port.
Explanation
Flex Link VLB detects a nontrunk port. [chars] is the interface name.
Recommended Action
Configure the interface to operate in trunking mode.
BADTRANSCEIVER Messages
This section contains the BADTRANSCEIVER message.
Error Message
BADTRANSCEIVER, PHY, LOG_WARNING: An innapropriate transceiver has
been inserted in interface [chars].
Explanation
This message means that a defective module is installed in the specified interface.
[chars] is the interface.
Recommended Action
Remove the transceiver. If it was purchased from Cisco, contact your Cisco
representative to have the transceiver replaced.