background image

120

Raption 50 Series User Manual

Value

Description

Authorization 
cache enabled

YES:

 maintain a local list of all presented identifiers that have 

been successfully authorized by the Central System.

NO: 

authorization for presented identifiers is requested directly 

to the Central System

Authorize remote 
Tx requests

YES:

 the Charge Point asks for authorization when the Central 

System sends a remote start

NO: 

the Charge Point starts the Charge Transaction when the 

Central System sends a remote start

Local pre-
authorize

YES: 

Charge Point looks for locally-authorized identifiers without 

waiting for the Central System authorization.

NO: 

Charge Point requests authorization for presented 

identifiers to the Central System.

Allow offline Tx for 
unknown Id

YES:

 during offline period unknown identifiers are allowed to 

start charging

NO: 

during offline period unknown identifiers are NOT allowed to 

start charging

Local authorize 
off-line

YES: 

during offline period locally-authorized identifiers are 

allowed to start charging

NO: 

during offline period locally-authorized identifiers are NOT 

allowed to start charging

Stop transaction on 
invalid Id

YES:

 

stop existing Charge Transaction after response from 

Central System when user is blocked, expired or invalid.

NO

:

 Charge Transaction does not stop even if backend rejects the 

user.

Summary of Contents for Raption 50 Series

Page 1: ...User Manual Raption 50 Series ...

Page 2: ......

Page 3: ... manual can be reproduced copied translated or transmitted in any form or by any means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result from its use All other pr...

Page 4: ......

Page 5: ...res 06 A Main features 06 B Overview 07 C Dimensions 08 D Status Beacon lights 09 E Connectors 10 3 How to use it 14 A General 14 B Starting a charging session 17 C Special events starting a charge 20 D Stopping a charging session 25 E Charging information 27 F Charging summary 30 ...

Page 6: ... A Introduction 40 B What is needed 41 C Network topology 42 D LAN connection procedure 43 E Setup Webpage 48 5 Communications 62 A Introduction 62 B Teltonika RUT240 configuration 63 C Sierra Wireless AirLink configuration 78 6 OCPP Integrations 88 A Introduction 88 B Previous requirements 89 C Starting up configuration 91 D Checking configuration 99 ...

Page 7: ...ent Overview 103 D CirCarLife client Devices 109 E CirCarLife client Graphs 118 F CirCarLife client Tables 121 G CirCarLife client Events 125 8 Output power setup 126 A Introduction 126 B Maximun output power for DC 127 C Maximun output power for AC 132 9 Technical Data 134 10 Need help 138 ...

Page 8: ...of in compliance with all requirements regarding IK indices In addition the Charge Point also has a communications system that allows monitoring and control remotely via OCPP and use XML parameters and information while the recharging is being performed This feature provides an easy way to integrate the Charge Point into superior systems that allow to the owner or system manager monitor it 1 Compl...

Page 9: ...s or manipulations with the unit energized Only trained and qualified personnel should have access to the electrical parts inside the Charge Point Check the installation annually by qualified technician Remove from service any item that has a fault that could be dangerous for users broken connectors caps that don t close Use only Circontrol supplied spare parts Do not use this product if the enclo...

Page 10: ...t connector Ethernet the unit allows communicate using TCP IP on an Ethernet network giving flexibility to the system operator and management of the Charge Point Remote monitoring and control in real time 3G 4G it can be done a remote device connection or make OCPP integrations thanks to the integrated modem In addition by using a standard Web browser you can access to the Charge Point to monitor ...

Page 11: ...0 CHAdeMO holder 11 CCS holder 12 AC holder or socket 32A 13 CCS light beacon 14 CHAdeMO light beacon 15 Antenna 16 Unit air outlet 17 Exit DC cable 18 Touch screen 19 Emergency button 20 RFID reader 21 Unit air inlet 22 PowerModules air inlet 23 CCS connector 24 Courtesy light 1 3 2 5 6 7 16 8 4 9 10 11 12 13 14 15 18 19 20 17 21 22 23 24 Depending of the model the components can vary ...

Page 12: ...08 Raption 50 Series User Manual C Dimensions Units specified in millimeters ...

Page 13: ...Available The connector or socket is available to start a charging session Blue Charging Theconnectororsocketisperformingachargingsession Cyan Booked OCPP 1 5 The connector or socket has been booked by system operator through OCPP Red Error TheChargingStationindicatesthattheemergencybutton hasbeenactivatedorsomeerrorhasoccurred Checkthe HMI Screen and follow the instructions ...

Page 14: ...ode 4 CHAdeMO Tethered cable 3m Until 125 A 50 kW DC Mode 4 Combo 2 CCS Tethered cable 3m Until 125 A 50 kW Depending of the model the components can vary E Connectors The following considerations before using this Charge Point must be considered Of the three types of charges that the Charge Point can perform it can carry out Only AC Only DC CHAdeMO Only DC CCS 2 Simultaneous AC and one DC connect...

Page 15: ...to pull back the connectors from holders without first unlocking it ThereareonelabelplacedbetweentheCHAdeMOandtheCCSholdersexplainingabout this function Follow the instructions given in this label and the HMI screen Also there is one Led over each holder indicating the lock state Red Connector locked Off Connector unlocked ...

Page 16: ...onnectors will be delivered right in the moment than the user push over the Connector touching button when choose the option in the HMI screen At the AC side for every Charge Point It is not an optional device there is a manual lock for keeping the connector follow the indications shown on the label in order to remove the AC connector ...

Page 17: ...13 ...

Page 18: ...tem will take around 10 seconds for starting up the screen will show next image In the lower right corner it shows the firmware version After that 10 seconds have passed the first screen that appears is the screensaver Tap over this screen and the HMI will skip to the next screen A General ...

Page 19: ...rging session to the user that has been registered in advance or has the identification card The second option touch the screen is only to get information about the connectors status and the charging process so as to know the Charge Point availability but you cannot start or do any action over the currently charging session Also atthisscreenandduringalltheprocessispossibletochangelanguage pressing...

Page 20: ...16 Raption 50 Series User Manual Next screen will appear press over your language s flag ...

Page 21: ...arging session Once you have shown your identification card the HMI will show next screen Wait while Charge Point performs identification If everything is correct and the user is authorized the HMI will show next screen ...

Page 22: ... available At any time is possible to press over this button in order to go back to the identification screen Once you have chosen your connector instruction screens will appear successively follow the instructions 1 Connect your vehicle and press the Start button At any time is possible to press over this button in order to go back to the previous screen ...

Page 23: ...ecking vehicle connection Please wait In a few seconds the charging session will start and the HMI will show the charging process Pressing over this button the screen will go back to the identification screen ...

Page 24: ... supervision of the main management system called Back Office It can generate a whitelist in order to register new users manage charging sessions etc If the user is not authorized the HMI will show the following message B Authorization failed if there is some communication problem with the Back Office right at the connecting time ...

Page 25: ...harge in this case the identifier is already involved in another charge transaction D Not authorized Authorization expired is possible that the back office has put deadline to your identification card and this date is already expired ...

Page 26: ...ntification card F After the user has been properly authorized and just at the moment that has to choose the connector the screen will show the connectors status it could appear some problem It is possible to use the connector painted in dark grey but it will be impossible to use any connector with another symbol or light grey like next ...

Page 27: ...ain and press over Retry button H Almost all vehicles cannot charge if the shift lever is not in parking mode position This situation can be detected for the Charge Point and it will be displayed by HMI as Please check vehicle shift position put in parking mode after press over Retry button ...

Page 28: ...24 Raption 50 Series User Manual I Is possible that the problem than appears is not a concrete one the HMI will show next screen press over Retry button ...

Page 29: ...rging process and next message Show your identification to stop the session can be stopped by the same user that has started it After showing your identification card the Charge Point will allow you to stop the charging session press over the Stop touch button ...

Page 30: ...26 Raption 50 Series User Manual Once you have stopped the charging session the HMI will show the summary screen press over the Exit touch button and disconnect your vehicle ...

Page 31: ...AC MODE 3 1 2 3 4 5 6 1 Language button pressing over this button it is possible to change the HMI language 2 Analog process indicator at first moment it is red as the vehicle is charging it will change to green passing before for orange 3 Charge time with status bar charging time elapsed so far 4 House touch button it goes back to the identification screen 5 Additional information current status ...

Page 32: ...orange 3 Battery SOC It indicates the current battery state of charge 4 Charge time with status bar charging time elapsed so far 5 House touch button it goes back to the identification screen 6 Additional information current status errors battery status etc 7 Remaining time until 80 remaining time until getting 80 of the SOC 8 Remaining time until 100 remaining time until 100 of the SOC 9 Energy c...

Page 33: ...en passing before for orange 3 Battery SOC It indicates the current battery state of charge 4 Charge time with status bar charging time elapsed so far 5 House touch button it goes back to the identification screen 6 Additional information current status errors battery status etc 7 Remaining time until 100 remaining time until 100 of the SOC 8 Energy charged energy supplied to the vehicle so far 1 ...

Page 34: ...ocess instructions different instructions can be displayed 3 Energy charged total energy charged at the end of the charging session 4 Stop reason It shows why the charging session has been stopped 5 Exit button It has to be pressed in order to finish the charging session After pressing the HMI screen will go back to the identification screen 6 Recharge time total recharging time at the end of the ...

Page 35: ...the end of the charging session 5 Exit button It has to be pressed in order to finish the charging session After pressing the HMI screen will go back to the identification screen 6 Stop reason It shows why the charging session has been stopped 7 Battery SOC It indicates the final battery state of charge at the end of the charging session 8 Information button pressing over this button you can get i...

Page 36: ...o do any charge All the power modules will shut down in order to protect the user and the own Charge Point The HMI screen will remain power up in order to show the instructions At first moment the Restart touch button will be in light grey and it will not be able for pressing onceyouhaveunlocktheemergencybutton the Restart touchbuttonwillbe in green and able to use ...

Page 37: ... for use This connector is out of service for any technical reason Pressover Information touchbuttoninordertogetmore information about it TheChargePointisoutofservicebecausetheemergency buttonhasbeenpressed Thisfactaffectsalltheconnectors at the same time Theconnectorisdisabled TheChargePointisoutoforder duetosomemaintenancejoborbecausetheBackofficehas decided to stop it ...

Page 38: ...user that has reserved the Charge Point is yourselfthechargingsessionwillstartnormally ifnot the Charge Point will not be able to charge until the date and time displayed have expired Only for DC connectors As the Charge Point only can performance one DC charging session at the same time CCS or CHAdeMO it could be possible to find one of these connectors with this symbol because the other is charg...

Page 39: ...35 I Consulting the connectors status Itispossibletopressovereachconnectorpicturetogetmoreinformationaboutthestatus 1 CONNECTOR ABLE 2 ERROR CONNECTOR ...

Page 40: ...36 Raption 50 Series User Manual 3 CONNECTOR DISABLE 4 CONNECTOR IN USE ...

Page 41: ...37 5 CONNECTOR RESERVED 6 CONNECTOR BLOCKED PER RESERVED ...

Page 42: ...38 Raption 50 Series User Manual 7 CONNECTOR BLOCKED PER CHARGING ...

Page 43: ...rgePointcanreportaboutdifferentsortoferrors itcanbefromdifferentpartsor devices from it When the Error screen appears the Information touch button has to be pressed in order to see the error message as you can see below ...

Page 44: ...blishedwiththe Charge Point direct access to the main setup page will be showed The Charge Point is shipped from the factory with default network setting of DHCP enabled ItmeansthattheChargePointwilltrytoobtainanIPaddressfromaDHCP server available on the network StepbystepbelowguidedetailedsetupanIPaddresstotheChargePointincasethere is no DHCP server available on the network A Introduction The Eth...

Page 45: ...ess to the Charge Point B What is needed ServicePCrunningMicrosoftWindows atleastWindowsXP UTP Cable Crossover recommended IPSetup exe CirCarLife Scada Client In order to get the software needed you can download it from http circontrol com downloads or contact with ps support circontrol com ...

Page 46: ...donewithstaticIPaddressand TCP IP v4 protocol Next section shows how to do this configuration Below image shows Ethernet connection topology and the IP addresses used in this guide as example For Service PC IP 192 168 1 10 NETMASK 255 255 255 0 For Charge Point IP 192 168 1 50 NETMASK 255 255 255 0 ...

Page 47: ...ep guide to connect the Service PC to the Charge Point in order to see real time status 1 On the Service PC click over the Network icon next to the clock of the taskbar and click on Open Network and Sharing Center 2 On the left pane click on Change adapter settings ...

Page 48: ...44 Raption 50 Series User Manual 3 Make right click on Local Area Connection and then click on Properties 4 Select Internet Protocol Version 4 TCP IP option and click on Properties ...

Page 49: ...5 5 Setup IP address and subnet mask like as shown here below and click OK twice to complete the assigning IP address process to the computer 6 Now execute IPSetup exe software provided on the Service PC ...

Page 50: ...following parameters and click on Configure MAC of the Charge Point see label on the cover s screen IP address i e 192 168 1 50 Netmask i e 255 255 255 0 Gateway leave default settings 8 Wait 30 seconds approximately until the process is complete ...

Page 51: ...te when the following message appears click on OK 10 If the message shown is the next one check the following parameters and click on OK Check IP address entered Check the MAC of the device entered Try with another UTP CAT5e cable ...

Page 52: ...ed to Charge Point it is possible to open Setup Webpage throug the IP entered In the example shown in the previous section it has been set 192 168 1 50 Open a web browser on the service PC and enter this IP next image will appear The webpage opened shows the Dashboard Overview as a main screen but there are many more options In the next points they will be explained ...

Page 53: ...iption Firmware version Version of the firmware currently installed in the Charge Point MAC Address Identifier of the network card of the Charge Point As a relevant information the Summary shows A Dashboard OVERVIEW ...

Page 54: ... this section it can be consulted the status of the devices which are communicating via RS 485 As a relevant information the Devices Status shows Value Description Device name Name of the devices inside the Charge Point Status OK online NOT OK offline ...

Page 55: ...s basically relative to the state of the PC of the Charge Point It is necessary for the technical service staff but does not show any information regarding to the external connection of the Charge Point or to the charging session SYSTEM STATUS ...

Page 56: ...ser Manual The information shown in this section refers to the drivers that the Charge Point needs in order to recognize the different devices inside the Charge Point such as the meters the mode 3 the RFID reader etc DRIVERS ...

Page 57: ...53 REPOSITORY SOURCES The information shown in this section is basically related to the internal behavior of the Charge Point ...

Page 58: ... of the charging sessions system performance or user activities When Charge Point is powered ON system begins to register log files If the Charge Point is restarted these logs are lost and immediately are created new ones However it is highly recommended to check log files in the next URL http IPADDRESS services cpi log SYSTEM LOGS ...

Page 59: ...ameters Value Description Hostname Name of the Charge Point on the network DHCP Enable or disable the IP address assignment by a DHCP server router To be enabled when working with the integrated modems In the table below there are explained the different sections of Network ...

Page 60: ...lular router is connected to the Charge Point SIERRA Wireless AirLink LS300 select this option only when SIERRA Wireless AirLink LS300 cellular router is connected to the Charge Point Circutor SGE 3G GPRS select this option only when Circutor SGE 3G GPRS cellular router is connected to the Charge Point Teltonika RUT240 LTE select this option only when Teltonika RUT240 LTE cellular router is connec...

Page 61: ...harge Point too Otherwise communication between modem and Charge Point will be lost Value Description Reset Web Password Charge Point will use default modem password after saving settings when selecting ON Web Password Introduce the new password that will be used on the modem side ...

Page 62: ...e Setup Webpage avoiding unauthorised access All parameters are disabled from factory settings Value Description Authentication ON authentication enabled OFF authentication disabled User Name Username and Password authentication for Setup web page Password Repeat password NOTE Do not forget the credentials There is no way to restart the Charge Point to default factory settings ...

Page 63: ... we will explain the different sections of the Time Value Description Time Zone Select the regional time for the Charge Point according to the location Time Current date and time of the Charge Point Primary NTP Server Synchronize the time through internet automatically Secondary NTP Server ...

Page 64: ... In Locale section there are two parameters that can be adjusted Value Description Locale Language can be selected here However it is prefered to use the section available in the Services section Currency Select the currency from your country ...

Page 65: ...s Clicking over the Integrations tab user will be able to activate OCPP integrations NOTE the integration of the Charge Point needs a separate chapter In the next chapter number 6 it is explained how to integrate OCPP ...

Page 66: ...not take in consideration any limit giving the maximum power for each connector Total Consumption Maximum current value offered by the Charge Point that shares between the ongoing Charge Transactions NOTE This value must be equal or higher than 6A multiplied by the number of outlets Meaning that it must be equal or higher than the sum of current delivered when all outlets are charging at the minim...

Page 67: ...guration is applied Before doing so make sure all fields are properly filled Consider that Master Charge Point reboots after clicking Save button More fields are shown when selecting a Slave charger model Do not perform these actions meanwhile a Charge Transaction is active ...

Page 68: ...ddress of the Slave Charge Point MAC Address MAC address of the Slave Charge Point Perform IP address assigment YES when clicking the Save button on the bottom of the web page the desired IP address is assigned to the Slave Charge Point with the MAC address specified NO when clicking the Save button on the bottom of the web page the Slave Charge Point with the IP address specified is added to the ...

Page 69: ...s Kit VISA or OCPP Integrations The payment will be done through one of these platforms As explained in the previous paragraphs this is just information for the final user When adjusting these settings they will be displayed in the charger screen even if there is not a platform in charge of the receipt Make sure that values are set according to the final price from these platforms Remember to pres...

Page 70: ...ew charge transaction Price per energy consumed Amount of money to be payed based on the energy delivered to the EV Price per time of charge Amount of money to be payed based on the duration of the charge transaction There are few parameters that can be adjusted All these settings can be combined according to the customer preferences ...

Page 71: ...play Clicking over the Services tab next image will appear Value Description Grid Test HMI shows a test screen to check that touch function works properly Default language It is possible to choose the default language for the HMI screen Screensaver Timeout for screensaver can be adjusted ...

Page 72: ...hat can be uploaded File must be ZIP format otherwise won t be accepted If a new ZIP file is uploaded previous images will be replaced by the new ones ZIP file up to 20 megas Every image up to 3 megas If image weight is higher than 3 megas it will be discarded Up to 25 different pictures Pictures are displayed in alphabetic order Accepted formats BMP GIF JPG JPEG PNG PBM PGM PPM XBM XPM Higher res...

Page 73: ...h this file HMI knows which drivers has to expect and which components should be communicating Those vary depending on the model of the charger A window will pop up in order to choose the file then click on upload To obtain the appropriate configuration file please contact CIRCONTROL Post Sales Department ...

Page 74: ...Firmware Through Firmware tab the Charge Point firmware can be upgraded remotely A window will pop up in order to choose the file then click on upload To obtain the latest firmware version please contact CIRCONTROL Post Sales Department ...

Page 75: ...71 ...

Page 76: ...ibes how to install the SIM card and setting up the modem The modem that has been installed in Raption series can be two models Teltonika RUT 240 or Sierra Wireless AirLink LS300 Step 1 Step 2 Steps 1 Open the right door of the Charge Point and locate the modem right on the rear side 2 Check that the Charge Point is provided with the antenna on the cover top A Introduction ...

Page 77: ...stalled from factory in the Charge Point is Teltonika RUT240 This device allows to the Charge Point connects over 4G networks to remotely view or manage the Charge Point status RUT240 is part of the RUT2xx series of compact mobile routers with high speed wireless and Ethernet connections ...

Page 78: ...S LED Explanation of connection status LED indication 1 Signal strength status LED s turned on router is turning on 2 2G and 3G LED s constant blinking every 1 sec no SIM or bad PIN 3 2G 3G LED s blinking every 1 sec connected 2G 3G but no data session established 4 Blinking from 2G LED to 3G LED repeatedly SIM holder not inserted 5 2G 3G LED turned on connected 2G 3G with data session 6 2G 3G LED...

Page 79: ...rt the SIM card 4 Push in the SIM holder After installing the SIM card check out that the 4G antenna mobile WiFi antenna and the power connector are properly attached Insert SIM card which was given by your ISP Internet Service Provider Correct SIM card orientation is shown in the picture NOTE SIM card is not provided with equipment ...

Page 80: ... with the setting up as described in the section above you are ready to start logging into your router and start configuring it This example shows how to connect through WiFi 4 1 At your service computer look for access point named RUT240_xxxxxxxxxxxx and connect on it ...

Page 81: ...me admim Password admin01 4 3 Configuration Wizard will start after logging in It is necessary to complete Configuration Wizard to setup modem to the correct mode Go to Status Network Mobile and pay attention to Sim card state field it has to be Ready You have now successfully logged into the RUT240 from here on out you can configure almost any aspect of your router See note in next page ...

Page 82: ...nd push over Save tab NOTES 1 If your SIM provider require any authentication ask them about what type PAP or CHAP select it on Authentication method field and introduce a password and username 2 If you need to do some custom over the modem configuration ask the Circontrol PS Support staff in order to get the Teltonika modem manual When using OCPP 1 5 do not change the default password for modem C...

Page 83: ...ion has been done properly check next steps Go to Status Network Mobile and pay attention to Data connection state it has to be Connected Go to Status Network WAN and pay attention to IP address the modem must has found a public IP address ...

Page 84: ...both your Service PC and the Charge Point NOTES 1 If the modem has not detected the automatic IP address switch off the Q10 1 circuit breaker wait for 10 seconds and switch on again Connect again your Service PC to the access point named RUT240_xxxxxxxxxxxx and repeat the steps 4 2 y 4 5 2 To make sure that the Charge Point s MAC number is correct it can be seen in one label behind the HMI screen ...

Page 85: ...e fields with next information Hostname It can be written the name that you want for your Charge Point MAC address It will be the MAC number found behind the HMI screen on the label IP address 192 168 1 50 After filling the fields push over Save button ...

Page 86: ...the Charge Point in order to do a hard reset over the modem and the HMI screen after 10 seconds switch ON again the MCB 4 8 Repeat again the points 4 1 and 4 2 explained above 4 1 look for modem access point and connect on it 4 2 log on modem webpage with authentication ...

Page 87: ...Status Network LAN DHCP Leases and confirm that the information written at the point 4 6 has been successfully recorded Hostname the name given for Charge Point MAC address the MAC of the Charge Point IP address 192 168 1 50 ...

Page 88: ...at you can see in the table below Name Protocol Externalport S Internal IP Internal port S 80 TCP 80 192 168 1 50 80 8080 TCP 8080 192 168 1 50 8080 50000 TCP 50000 192 168 1 50 50000 9191 TCP 9191 192 168 1 1 80 After noting down the ports push over Save button and check that all of them has been successfully introduced ...

Page 89: ...85 4 11 Go to Network Firewall Traffic Rules Roll down again and push over Save button Roll down and look for Enable_HTTP_WAN and Enable_HTTPS_WAN fields and enable these ...

Page 90: ... a reboot Go to System Reboot and push over the Reboot tab During the process the system will show the progress do not switch off the modem 4 13 Repeat again the points 4 1 and 4 2 explained above 4 1 look for modem access point and connect on it 4 2 log on modem webpage with authentication ...

Page 91: ... and DHCP is ON at Charge Point s setup webpage Make sure that your Service PC is still connected with the Charge point through wifi open a web browser and type 192 168 1 50 next screen will appear DCHP ON Address Type Teltonika RUT240 LTE Click over the Disk symbol tab in order to save ...

Page 92: ...Wireless AirLink LS300 1 MODEM OVERVIEW The 3G modem installed from factory in the Charge Point is Sierra Wireless AirLink LS300 This device allows to the Charge Point connects over 3G networks to remotely view or manage the Charge Point status ...

Page 93: ...een the device is connected to power Activity when green the radio link is active Signal when green it is receiving a cellular signal Network when green the device is connected to a cellular network with an IP address assigned and a channel acquired LED Colors The four front panel LEDs show the status of various items and can be used as a troubleshooting aid They are multi colored Off No activity ...

Page 94: ...power mode or system low level boot Green The device is connected to nominal power and is operating normally Green with a momentary yellow flash The device has a GPS fix Activity LED This shows the radio s activity Off The LED s normal appearance Flashing green The radio is transmitting or receiving Signal LED This shows the cellular network s signal level Flashing red No signal is present RSSI 11...

Page 95: ...r network Yellow The cellular network is found and the device is connecting Flashing yellow The cellular network is unavailable The device was unable to authenticate on the network Green Connected to the cellular network Flashing Green The device is roaming 3 SIM CARD INSTALLATION Explanation of SIM card installation Disconnect the power supply for modem and insert the SIM card which was given by ...

Page 96: ...or are properly attached NOTE SIM card is not provided with equipment 4 LOGGING IN Plug again the power supply for the modem NOTE After plugging back the modem it can take until 5 minutes to respond 3G modem configuration is performed using the Ethernet interface Connect your Service PC using an Ethernet cable as shown in the following image Set the IP number 192 168 13 50 on your laptop following...

Page 97: ...r login screen appears Default user name is user and default password is 12345 Do not change the default credentials the Charge Point requires consulting information from the 3G modem 4 2 The ACE manager homepage appears You can now configure each device with ACE manager Make click over WAN Cellular tab ...

Page 98: ...OCPP Listening port is 50000 by default If your Central System works with a different port add this one instead in OCPP web settings http IP_ADDRESS 8080 and into the Security tab of Sierra modem Fill each field according to the next picture Setup Webpage OCPP Incoming listening ports OCPP Settings SCP Remote Access 80 50000 8080 22 NOTE The OCPP Listening port is 50000 by default If your Central ...

Page 99: ... Click over Reboot button and wait for 3 4 minutes After that the modem should has found a public IP Check it in the Status tab Connect the modem to the unit again If the process has been done properly we should have remote access to the Charge Point using the public IP from the step before ...

Page 100: ...less AirLink LS300 modem option is chosen and DHCP is ON at Charge Point s setup webpage Using the public IP from the step before open a web browser and type it next screen will appear DCHP ON Address Type Sierra Wireless AirLink LS300 Click over the Disk symbol tab in order to save ...

Page 101: ...97 ...

Page 102: ...CPP is to offer a uniform solution for the communication between Charge Point and a Central System With this open protocol it is possible to connect any Central System with any Charge Point regardless of the vendor Follow next steps in order to configure OCPP 1 5 in the Circontrol Charge Points ...

Page 103: ...address in order to send it later to the backend Different values can be selected in the Address Type section Choose the option selected under Address Type according to your network topology Check following steps in order to ensure the correct function of OCPP 1 5 When done please do not forget to save changes using Save button in the upper right bar ...

Page 104: ...ame time Go back to setup web page and click on the Integrations tab choose the option selected under Available integrations according to your backend policies as shown in the picture NOTE Charge Point is working as stand alone if none option is selected All ID cards are authorized to start stop a new charge transaction and no requests are sent to the backend ...

Page 105: ...w tabs are opened to show OCPP Settings It can also be accessed directly typing http IP 8080 html setup html These tabs require a user identification User admin Password 1234 First time is running the integration selected on the Charge Point it starts as configuration mode and all fields are empty Settings are always stored even when the Charge Point is powered off or even the integration is disab...

Page 106: ...Description ID Charge Point identifier Public IP timeout Maximum waiting time to obtain the public IP address of the 3G modem OCPP Internal port Incoming listening port for remote request internal OCPP Public port Incoming listening port for remote request public Client Certificate Provided by the Central System Protocol If HTTPS is selected make sure to have CS Server CA certificate Authenticatio...

Page 107: ...s Check Central System URL according to the backend policies please contact to the Central System to get the configuration parameters Value Description ID Tag Endianness Storage type for system data Host URL URL address of the central system Authentication It can be set an authentication for avoinding changes in this page ...

Page 108: ...PP Settings tab Check OCPP Settings according to the backend policies please contact to the Central System to get the configuration parameters Before making any changes read following table and set each option according to your backend provider ...

Page 109: ...uthorize always in offline mode YES If user is not present locally in the local white list and charge point cannot ask to the backend user is allowed to start a new charge transaction NO If user is not present locally in the local white list and charge point cannot ask to the backend the user is not allowed to start a new charge transaction Retry after CS internal error YES Enabled If StatusNotifi...

Page 110: ...his function Energy for Start Stop transaction PARTIAL Consumed value of energy by the vehicle sent between start and stop TOTAL actual count of the total accumulated energy meter sent between start and stop Energy for MeterValues PARTIAL Sends partial energy consumption while vehicle is charging TOTAL sends the actual count of the total accumulated energy meter Stop charge if StartTrans action re...

Page 111: ...ting a new remote charge transaction request NO Charge point starts a new remote charge transaction without authorization request Active Power in MeterValues YES Send power Power Active Import and energy Energy Active Import Register consumed by the vehicle within meter values requests NO Only energy consumed is sent within meter values request Heartbeat interval Heartbeat send interval in seconds...

Page 112: ... User Manual Once done please do not forget to save changes using Save button in the upper right bar Please wait until the new configuration is being applied to the Charge Point A message is displayed informing the progress ...

Page 113: ... the message shown is Registering CB in the CS failed then check following items Backend URL Case sensitive Check all the URL is correct Charge Point ID Case sensitive Check if the name entered is same as backend expects to receive Connectivity Check if modem is power up and connected to the HMI screen Ask to the backend provider if any request has been received from the charge point BootNotificat...

Page 114: ...OCPP is to offer a uniform solution for the communication between Charge Point and a Central System With this open protocol it is possible to connect any Central System with any Charge Point regardless of the vendor Follow next steps in order to configure OCPP 1 6 in the Circontrol Charge Points ...

Page 115: ... IP address in order to send it later to the backend Different values can be selected in the Address Type section Choose the option selected under Address Type according to your network topology When done do not forget to save changes using Save button in the upper right bar Check following steps in order to ensure the correct function of OCPP 1 6 ...

Page 116: ...ck on the Integrations tab choose the option selected under Available integrations according to your backend policies as shown in the picture NOTE Charge Point is working as stand alone if none option is selected All ID cards are authorized to start stop a new charge transaction and no requests are sent to the backend License required refer to the next chapter for more information about the activa...

Page 117: ... does not have the license applied the following message pops up To obtain the license file please contact CIRCONTROL Post Sales Department More information in Need help chapter The license can be applied by clicking on the Select File button C ...

Page 118: ...114 Raption 50 Series User Manual A window will pop up in order to choose the file then click on upload ...

Page 119: ...w tabs are opened to show OCPP Settings It can also be accessed directly typing http IP 8080 html setup html These tabs require a user identification User admin Password 1234 First time is running the integration selected on the Charge Point it starts as configuration mode and all fields are empty Settings are always stored even when the Charge Point is powered off or even the integration is disab...

Page 120: ... Series User Manual On the OCPP webpage go to Charge Box tab Check Charge Box Identity and the incoming ports according to the backend policies please contact to the Central System to get the configuration parameters ...

Page 121: ...ate and time Disabled NOTE Date and Time is sent from backend on each heartbeat response Energy for Start Stop transaction PARTIAL Consumed value of energy by the vehicle sent between start and stop TOTAL actual count of the total accumulated energy meter sent between start and stop Energy for MeterValues PARTIAL Sends partial energy consumption while vehicle is charging TOTAL sends the actual cou...

Page 122: ...e the central system is hosted to notify all the requests Check Central System URL according to the backend policies please contact to the Central System to get the configuration parameters Value Description ID Tag Endianness Storage type for system data Host URL URL address of the central system ...

Page 123: ...119 Go to OCPP Settings tab Check OCPP Settings according to the backend policies please contact to the Central System to get the configuration parameters ...

Page 124: ...rized identifiers without waiting for the Central System authorization NO Charge Point requests authorization for presented identifiers to the Central System Allow offline Tx for unknown Id YES during offline period unknown identifiers are allowed to start charging NO during offline period unknown identifiers are NOT allowed to start charging Local authorize off line YES during offline period loca...

Page 125: ...er to unlock the connector Supported profiles List of supported profiles on the Charge Point NOTE this field is for information purposes it cannot be modified Maximum number of configuration Keys Maximum number of requested configuration keys that can be requested by the Central System NOTE this field is for information purposes it cannot be modified Heartbeat interval Number of seconds between He...

Page 126: ...bled NO Local Authorization List disabled Local auth list max length Maximum size of the Local Authorization List a list of identifiers that can be synchronized with the Central System It can be viewed accessing to the following URL http IP 8080 services cmd dump_localList xml NOTE this field is for information purposes it cannot be modified Send local list max length Maximum number of identificat...

Page 127: ...en Charge Point is properly connected to the back end Otherwise if the message shown is Registering CB in the CS failed then check following items Backend URL Case sensitive Check all the URL is correct Charge Point ID Case sensitive Check if the name entered is same as backend expects to receive Connectivity Check if modem is power up and connected to the HMI screen Ask to the backend provider if...

Page 128: ... circarlife com en downloads NOTE Java software needs to be installed on your computer in order to run the client software please download last version from www java com In remote connections where is required communicate via 3G 4G data with the Charge point in order to monitor its parameters it should be noted that there will be a HIGH consumption of data In the case of doing the Charge point mon...

Page 129: ...125 Monitoring Steps 1 Execute CirCarLife Client software at your computer 2 Push on General tab and after on Connect tab B CirCarLife client Connection ...

Page 130: ...126 Raption 50 Series User Manual 3 Enter the IP address given to the Charge Point and port number 80 after press over Ok Once you have done the previous steps it is possible to monitor the Charge Point ...

Page 131: ...of the Charge Point Client platform is implemented in Java and can be executed on many devices 1 4 2 3 NOTE devices connected to the Charge Point may vary depending on model purchased CirCarLife Scada client is divided on 4 sections 1 Menu bar 2 Toolbar 3 Screen information 4 Status bar Following section describes in detail each of the points mentioned above ...

Page 132: ...es There are three main menus Options Views and General Options Option Description Properties Displays properties of the currently active view Print Print currently active view Export Exports currently active view Exit Close the CirCarLife client software Note this option can be active or not depending on the view in progress ...

Page 133: ...ext view If available Historic Displays any view previously consulted Study Displays graph and tables views Devices Display the general status of all connected devices Events Displaystheeventslogortheactiveeventswindow Devices status Display the general status of all connected devices ...

Page 134: ...een Charge Point and computer connected Internal toolbar Not available tab Event actions List of actions enabled in the CirCarLife software Time zone It lets to change the time over GMT Connect Connects with the Charge Point monitored Language Changes the CirCarLife client software language Graphs properties Changes graph appearance About Displays client application version information General ...

Page 135: ...es a table about the charging session Events Displays event history Properties Displays the properties window of the current view Print Allows us to print the current view 2 TOOLBAR Toolbar contains the most frequent options used in the CirCarLife client software It is possible to hide or display buttons for the toolbar Doing right click on the toolbar and following setup menu will appear ...

Page 136: ...tatus Engine name IP and port Incidences Status Description OnlineCirCarLifeScadaengineandworkingproperly Offline CirCarLife Scada engine Incidences Description One or more devices are not communicating See device status section to find witch device is not communicating One or more devices are not reporting One or more events are active NOTE Double click over each icon will show the details ...

Page 137: ...CirCarLife client software In this case we are going to explain about Devices icon The A8 device refers to the HMI screen it is reserved to the factory no change has to be made in this tab The AC Meter refers to all the electrics parameters that can be read regarding the AC charge session ...

Page 138: ...134 Raption 50 Series User Manual The AC Mode 3 tab refers to the Mode 3 device after pressing on this tab press on Properties tab and on Advanced in order to see more details about Mode 3 device ...

Page 139: ...tatus only socket models Locked plug Unlocked plug Recharge Recharge status Starts a charge from remotely point Stop charging in progress Power reduction Power reduction Status It activates the power reduction it is based on a percentage going down from the total AC power This tab deactivates the power reduction and the charger is bound to give the total AC power ...

Page 140: ...age is being supplied to the vehicle No voltage is being supplied to the vehicle Charge begin date Startingdateofthelastchargesession Charge end date Ending date of the last charge session Charge time Duration of the last charge session Last charge stop Reasonforthelastchargesessionstop Analog value code cable Reserved value for factory Value code cable A Max currentcapacityfortetheredcable Analog...

Page 141: ...session but upstream of the power modules reading AC consumption At this tab DC Mode 4 it can be seen a lot of parameters regard to the DC charging sessions for both kind of charges CHAdeMO and CCS The most important how to setup the output power will be explained in the next points in this document ...

Page 142: ...138 Raption 50 Series User Manual The EVSE tab is useful so as to see a quickly view of the currently charging session for both kind of charges started in that moment DC and AC DC Side AC Side ...

Page 143: ...hts can be switched on from here without touching the screen It switches off the courtesy lights Reserved Reserved status It lets to activate the charging session for one specific identifier tag It deactivates the option Leakage Shortcircuit RCD MCB status Normal operation The device has tripped If for any reason such as mainte nance work and the RCD or MCB has remote control it is possible to swi...

Page 144: ...harge point s door it is possible to Reset the unit Active energy kWh Totalchargepoint smeasuredenergysinceinstalled Partial active energy kWh Partial energy meter of the last charging session Active power kW Active power for the active charging session Voltage V Present voltage of the active charging session Current A Present amps of the active charging session Charge request date Date of the las...

Page 145: ...1 Clicking over Reader tab it can be checked if the reader is working properly reading the RFID identifier The identifier number will appear for a short time meantime the RFID card is shown to the reader ...

Page 146: ...rogress for the device choosen in advance it means if it choosen a device on the Device tab and after the Graph icon is pressed at the TOOLBAR the graph shown will make reference to this device As an example we are going to show the graph for EVSE device Following image shows the variables selection that can be done in order to show after in the graphs for both DC and AC charging session ...

Page 147: ...area contains some common characteristics Key provides general information about the variables represented in the area Y Axis provides information on the units of the variables that are represented in this axis and the range of values that are being displayed X Axis typically this is the time axis and is located at the bottom of the representation area Here the time interval being represented may ...

Page 148: ...toolbar contains a series of actions that can be performed on the graph Depending on the type of graph it will contain more or fewer options Option Description Back Displays the previous interval of data Next Displays the next interval of data Go to Allows choosing a closed graph interval Grouped by Allowschoosingstandardgraphinterval byday week monthoryear Period Sampling period variables ...

Page 149: ... Device tab and after the Table icon is pressed at the TOOLBAR the table shown will make reference to this device As an example we are going to show the table for EVSE device Once the Table button is pressed a discriminator window appears there are two types of tables Standard sampling variable energy power voltage depending on the meter installed on the charge point Choose Standard and after pres...

Page 150: ...charges on the charge point Choose Recharge and after press over OK Following image shows the appearance of Standard table Now another pop up window appears you can choose either DC or AC and after choose the variables to be shown such as Active energy Active power Current and voltage ...

Page 151: ... over Ok Following image shows the appearance of Standard table Table tool has following sections Title data period displayed Body it contains a series of columns with the values registered Toolbar personalization data showed in the table Tabletoolbarhassameoptionsandfunctionalityasexplainedontoolbargraphssection ...

Page 152: ... next Using this option it is possible to add new variables to the table in the same way as they are added to the graph by clicking on Add It is also possible to delete variables from the table selecting the desired variables and clicking on the Remove button User can print or export the current table displayed using Print or Export option on the Options menu of the Menu bar ...

Page 153: ...feScadaclientenablescurrenteventstobeviewedinrealtime boththesimple events that are active and those that must also be acknowledged by the user NOTE this option is not able for Raption s Series because all this functions can be done by OCPP ...

Page 154: ...nectedthroughtheprogramCirCarLife Client software LimitingtheoutputpowerwillbeusefuliftheinputpowersupplyfortheChargingPointis not enough powerful to feed and keep a good level of charge for electric vehicles The power reduction can be done for both DC and AC outlet DC output power can be limited in watts AC output power can be limited in amps A Introduction ...

Page 155: ...151 Output power setup Steps 1 Execute CirCarLife Client software 2 Push on General tab and after on Connect tab B Maximum output power for DC ...

Page 156: ...ress given to the Charge Point and port number 80 after press over Ok 4 Press on the Device tab icon at the TOOLBAR and after click on DC Mode 4 NOTE inside DC mode 4 is necessary to modify the output power for both DC charges type CHAdeMO and Combo CCS ...

Page 157: ...153 5 Once the DC Mode4 device is already opened press over the CHAdeMO General 1 tab 6 Once the CHAdeMO General 1 is already opened press over Setup tab ...

Page 158: ...ow appears at Limit Power tab it is possible to set the maximum DC power output it can be selected from 10000 W til 50000 W Click OK to confirm changes NOTE It is mandatory write the same variables for CHAdeMo as for Combo CCS Do not change any other vaiable ...

Page 159: ...over Combo General 1 tab and then over Setup tab 9 Force the Limit power variable between 10000 W til 50000 W as has been shown in the previous step 7 for CHAdeMO Click OK to confirm changes NOTE It is mandatory write the same variables for CHAdeMo as for Combo CCS Do not change any other vaiable ...

Page 160: ...utput power for AC is necessary to use de software Charge Point Setup ask for it to the CIRCONTROL technical support staff Steps 1 Execute Charge Point Setup 2 Introduce the Charge Point s IP and push over Connect tab 3 Write down the Max Current per plug A and push over Apply settings tab ...

Page 161: ...157 ...

Page 162: ...5 Kg Dimensions D x W x H 410 x 940 x 1800 mm GENERAL DATA Display TFT 8 Multi language touch screen Light beacon RGB Colour indicator RFID reader ISO IEC 14443A B MIFARE Classic Desfire EV1 ISO 18092 ECMA 340 NFC 13 56MHz Compliance IEC 61851 IEC 62196 CE CHAdeMO Certified CCS DIN 70121 Rated diversity factor 0 8 ENVIRONMENTAL CONDITIONS Operating temperature 30ºC to 45ºC Storage temperature 20ºC...

Page 163: ...n 38 W THDi 5 Frequency 50 60 Hz Electrical protections Overcurrent protection RCD and Overvoltage protection AC electrical meter Complies with the EN 50470 MID European standards CONNECTIVITY Ethernet 10 100BaseTX TCP IP Cellular Modem 4G GPRS GSM Interface protocol OCPP Depending on the model these components are optionals 520 mm with the cables hanged ...

Page 164: ...m output power DC 50 kW AC 44 kW DC 50 kW AC 22 kW DC 50 kW DC 50 kW AC 22 kW Output voltage range DC 50 500 VDC AC 400 VAC DC 50 500 VDC AC 400 VAC DC 50 500 VDC DC 50 500 VDC AC 400 VAC Maximum output current DC 0 125 A AC 63 A DC 0 125 A AC 32 A DC 0 125 A DC 0 125 A AC 32 A Number of connectors 3 3 2 2 Connector type CCS2 JEVS G105 Type 2 tethered cable CCS2 JEVS G105 Type 2 socket CCS2 JEVS G...

Page 165: ...pply capacity 75 KVA 53 KVA 53 KVA Maximum output power DC 50 kW AC 22 kW DC 50 kW DC 50 kW Output voltage range DC 50 500 VDC AC 400 VAC DC 50 500 VDC DC 50 500 VDC Maximum output current DC 0 125 A AC 32 A DC 0 125 A DC 0 125 A Number of connectors 2 1 1 Connector type JEVS G105 Type 2 socket CCS2 JEVS G105 ...

Page 166: ...162 Raption 50 Series User Manual 10 ...

Page 167: ...163 Need help In case of any query or need further information please contact our Post Sales Department 34 937 362 940 34 937 362 941 ps support circontrol com circontrol com ...

Page 168: ...CIRCONTROL Raption 50 Series USER MANUAL A comprehensive guide on how to use and configure your Raption 50 Charge Point V1 5 April edition 2020 CIRCONTROL S A ALL RIGHTS RESERVED R216 ...

Reviews: