06
Raption 50 Series Instruction Manual
2
A
Main features
• HMI: there is a TFT colour touch screen of 8 inches, is the interface between the
Charge Point and the user. Provides detailed information for starting and stopping
the charge, including information concerning the recharge that is in progress
(charge state of the battery, charging time remaining, etc).
• RFID: there is a radio frequency reader that allows user authentication to proceed
with the recharging of the electric vehicle. At the discretion of the facility operator,
the user’s recharge also can be allowed or denied.
• User Management: provides a database that associates users with one or more
identification cards, you can also assign consumption and charging logs.
• Beacons light: by a LED beacons located above connectors, it is indicated the
charging status of the socket/connector.
• Ethernet: the unit allows communicate using TCP / IP on an Ethernet network,
giving flexibility to the system operator and management of the Charge Point.
• Remote monitoring and control in real-time 3G/4G: it can be done a remote device
connection or make OCPP integrations thanks to the integrated modem. In addition,
by using a standard Web browser, you can access to the Charge Point to monitor the
status of recharge and even run a Start / Stop remote.
• Historic charge transactions: the system is able to generate charging process
reports, according to the historical database of the Charge Point.
• Energy metering: Integrated meter, independent for AC and DC, is measuring
power and energy consumed by the EV during a charge session.
• OCPP integration: OCPP is a communication protocol between the Charge Point and
management platforms (BackOffice) for comprehensive management of charging.
This integration allows, among other things, management and user authentication
as well as a variety of parameters to monitor during a recharge.
Summary of Contents for Raption 50 Series
Page 1: ...User Manual Raption 50 Series ...
Page 2: ......
Page 4: ......
Page 12: ...08 Raption 50 Series User Manual C Dimensions Units specified in millimeters ...
Page 17: ...13 ...
Page 20: ...16 Raption 50 Series User Manual Next screen will appear press over your language s flag ...
Page 40: ...36 Raption 50 Series User Manual 3 CONNECTOR DISABLE 4 CONNECTOR IN USE ...
Page 41: ...37 5 CONNECTOR RESERVED 6 CONNECTOR BLOCKED PER RESERVED ...
Page 42: ...38 Raption 50 Series User Manual 7 CONNECTOR BLOCKED PER CHARGING ...
Page 75: ...71 ...
Page 101: ...97 ...
Page 161: ...157 ...