117
Value
Description
ID
Charge Point identifier
Cache max. size
Maximum size of the
Authorization Cache, that autonomously
maintains a record of previously presented identifiers that have
been successfully authorized by the Central System.
It can be viewed accessing to the following URL:
http://<IP>:8080/services/cmd/dump_cache.xml
Use OCPP time
synchronization
YES:
Synchronization of date and time -> Enabled.
NO:
Synchronization of date and time -> Disabled.
*NOTE:
Date and Time is sent from backend on each heartbeat
response.
Energy for Start/
Stop transaction
PARTIAL:
Consumed value of energy by the vehicle sent between
start and stop.
TOTAL:
actual count of the total accumulated energy meter sent
between start and stop.
Energy for
MeterValues
PARTIAL:
Sends partial energy consumption while vehicle is
charging.
TOTAL:
sends the actual count of the total accumulated energy
meter.
User confirmation
required on remote
start
ON:
user confirmation needed to proceed with a remote start (i.e.
touch the screen)
OFF:
user confirmation NOT needed to proceed with a remote
start
Summary of Contents for Raption 50 Series
Page 1: ...User Manual Raption 50 Series ...
Page 2: ......
Page 4: ......
Page 12: ...08 Raption 50 Series User Manual C Dimensions Units specified in millimeters ...
Page 17: ...13 ...
Page 20: ...16 Raption 50 Series User Manual Next screen will appear press over your language s flag ...
Page 40: ...36 Raption 50 Series User Manual 3 CONNECTOR DISABLE 4 CONNECTOR IN USE ...
Page 41: ...37 5 CONNECTOR RESERVED 6 CONNECTOR BLOCKED PER RESERVED ...
Page 42: ...38 Raption 50 Series User Manual 7 CONNECTOR BLOCKED PER CHARGING ...
Page 75: ...71 ...
Page 101: ...97 ...
Page 161: ...157 ...