A.4 Power Requirements
A.4.1
AC Input (A)
Voltage Range
200 - 240 VAC
Line Frequency
50 Hz - 60 Hz nominal
Inrush Current
<110 A maximum
Current Consumption
16 A maximum (at 200 VAC)
Power Consumption
3200 W maximum
Current Rating of AC Input
IEC-320-C19/20 A
Line Cord Plug Type
NEMA 6-20P
NOTE:
Below 200VAC, when the lamp is ignited, a 25 A input surge current might occur for three seconds.
A.4.2
UPS AC Input (B)
Activation
Discrete switch above the power inlet cord(s)
UPS inlet connector
(rating for powering main electronics)
IEC-320-C13/10A, 240VAC
UPS Type
Universal 100-240VAC
Ballast Power AC Plug Type/Current rating
IEC-320-C19/20 A
(on projector)
A.5 Lamp
Type:
Xenon Short Arc Lamp
Power (software adjustable):
CDXL-14M
700W min., 1430W nom., 1575W max.
CDXL-16M
1000W min., 1600W nom., 1760W max.
CDXL-21S1
1260W min., 2100W nom., 2100W max.
NOTE
: The ballast is power regulated and has a maximum current of 97A. Therefore the maximum power
specification for a given lamp may not be achievable until the lamp has aged, since lamp voltage increases
with hours of use.
Average Life:
CDXL-14M
3500 hours
CDXL-16M
3500 hours
CDXL-21S1
1500 hours
Wait time between lamp strikes
2 minutes minimum
Warm up time to full brightness
20 minutes maximum
NOTE
: Projectors typically force a 10 minute cool down period. Ensure you do not re-strike the lamp any
sooner than 2 minutes into this cool down period since hot re-strikes reduce lamp life.
Summary of Contents for Solaria One
Page 1: ...Solaria One U s e r M a n u a l 020 100841 02 ...
Page 2: ......
Page 3: ...Solaria One U S E R M A N U A L 020 100841 02 ...
Page 6: ......
Page 14: ......
Page 50: ......
Page 56: ......
Page 60: ......
Page 64: ......
Page 76: ......
Page 78: ......
Page 120: ......
Page 134: ......