16-2
Solaria One User Manual
020-100841-02 Rev. 1 (11-2012)
• Listen for a clicking noise that indicates the ballast is attempting to strike the lamp. If you do not hear a click-
ing noise, there might be a problem with the ballast. Contact a Christie accredited service technician to
resolve the issue.
• If you hear a brief clicking noise, but the lamp does not ignite, replace the lamp.
Lamp Suddenly Turns Off
• Tap
Menu
>
Advanced Setup
>
Lamp Power/LiteLOC Setup
. Increase the lamp power.
• Tap
Menu
>
Status
and then
Interlocks
in the left pane. Review and correct all interlock failures.
• Tap
Menu
>
Status
and then
Temperatures
in the left pane. Verify if the DMD temperatures are too high. If
the temperatures are too high, cool the projector. Ensure the projector is properly ventilated and the air filters
are not blocked.
• Replace the lamp.
LiteLOC
™
Not Working
• Tap
Menu
>
Advanced
Setup
>
LampPower/LiteLOC™ Setup.
Tap
Enable LiteLOC
™
.
• If the lamp power is at the maximum setting to maintain a LiteLOC™ setting, LiteLOC™ is automatically
disabled. Reduce the LiteLOC™ setting, or install a new lamp.
16.3
Display Issues
Flicker, Shadows, or Dimness
• Ensure the douser is open.
• Align the lamp. See
Align the Lamp on page 1-18.
• Tap
Menu
>
Advanced
Setup
>
LampPower/LiteLOC™ Setup
. Monitor the
Power %
field to determine
if the power is consistent or if it varies. Increase the lamp power. Lamps which are near end of service may
not operate reliably at a lower power setting.
• Fold mirror misalignment. Contact your Christie accredited service technician to resolve the issue.
• Integrator rod misalignment. Contact your Christie accredited service technician to resolve the issue.
Blank Screen, No Display of Cinema Image
• Ensure the lens cap is not on either end of the lens.
• Ensure the lamp is
ON
.
• Confirm all power connections are still OK.
• Ensure the douser is
OPEN
by verifying the state of the douser on
Main
panel.
• Ensure any test pattern other than the full black test pattern displays properly.
• Verify the correct display file is selected.
• For cinema connections, verify the correct port is selected.
Severe Motion Artifacts
Verify if there is a synchronization problem with reversed 3-2 pull-down in the 60Hz-to-24Hz film-to digital
conversion and correct it at the source.
Summary of Contents for Solaria One
Page 1: ...Solaria One U s e r M a n u a l 020 100841 02 ...
Page 2: ......
Page 3: ...Solaria One U S E R M A N U A L 020 100841 02 ...
Page 6: ......
Page 14: ......
Page 50: ......
Page 56: ......
Page 60: ......
Page 64: ......
Page 76: ......
Page 78: ......
Page 120: ......
Page 134: ......