Chapter 2
2-11
5) Under the conditions of step 4, pull the Solenoid Unit in the direction of
the arrow and secure it with a screw.
6) Slide the Solenoid Pin [1] and check that the Shutter [2] opens and closes
smoothly.
7) Check that the Shutter [2] is completely opened and that all parts of the
sensor measurement area [3] are visible when the Solenoid Pin [1] is pulled.
The sensor measurement area should not be visible when the Drum Patch
Sensor Shutter is closed.
8) If the Shutter does not open/close smoothly, perform "CAUTION: Points
to Note when Installing the Drum Patch Sensor Shutter Solenoid Unit (when
the Solenoid Pin with Wire Came Off of the Guide)" again to rework the
installation.