[Note] Since the alignment plate is installed a bit tilting toward the delivery direction, set the paper to be fitted to the edge (on the
delivery side).
4) Enter the gap value measured in the above step 3) in the calculation formula below, enter the calculated adjusted value [a]
and press OK [b].
Adjusted value = gap (mm) x 10 - 50
[Note] Correspondence table of measured gap value and adjusted value.
Gap mm (measured value)
adjusted value
2.0
- 30
2.5
- 25
3.0
- 20
3.5
- 15
4.0
- 10
4.5
- 5
5.0
0