A-4) Reassemble the part in reverse order of Step A-2).
A-5) Perform the action which caused the symptom to confirm if the symptom does not occur any more.
B) Check the attaching states of Toner supply sensor and Sensor flag.
B-1) Remove the First Delivery Tray referring [Removing the Bottle Drive Unit].
B-2) Check the attaching states of Toner supply sensor and Sensor flag.
E025-0110/0210/0310/0410 occurs when the attaching state is in poor condition (floating/coming off condition).
If the attaching state is poor (floating/coming off ), correctly attach them again and proceed on to Step B-3).
If the attaching state is proper, check another measure.
B-3) Reassemble the part in reverse order of Step B-1).
B-4) Perform the action which caused the symptom to confirm if the symptom does not occur any more.
C) Check if the lock levers of Bottle Drive Units are unlocked.
C-1) Remove the Black and Magenta of Toner Bottle Mount (Lower) referring [Removing the Bottle Drive Unit].
C-2) Pull out a lock lever [a] of Bottle Drive Unit to the front side by hand until it stops.
If a lock lever of Bottle Drive Unit is not unlocked, the lock lever slides about 5mm to the front side. If a lock lever is unlocked, the
lock lever does not slide.
E025-0110 occurs when the lock lever of the left side Bottle Drive Unit is not unlocked, E025-0310 occurs when the lock lever of
the right side Bottle Drive Unit is not unlocked.
146
Summary of Contents for imageRUNNER ADVANCE C3330 Series
Page 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Page 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Page 105: ...If the symptom does not improve check other causes 100 ...
Page 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Page 144: ...139 ...
Page 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Page 197: ...Inner Finisher G1 EX QVA10470 192 ...