White Line appearing in sub scanning direction on image due to
fluff adhered to the laser exposure path or waviness of Developing
Unit sheet
[Symptom]
A sharp white line [a] may appear in the sub scanning direction on an image.
The arrow [b] indicates the direction of feeding.
[Cause]
If fluffy foreign matter is adhered to the laser exposure path which is located between the Laser Scanner Unit and the Developing
Unit or if the Developing Unit sheet is wavy, the laser light is blocked and a latent image cannot be formed. As a result, the
symptom occurs.
[Service work]
1) Open the Front Cover of the machine, and open the Drum Unit Retaining Cover [1] of the color in question.
2) Hold the light-blue [A] part, and pull out the Drum Unit [1].