C-3) Reassemble the part in reverse order of Step C-1).
C-4) Perform the action which caused the symptom to confirm if the symptom does not occur any more.
If the lock levers do not slide (are unlocked), perform another measure.
D) Check if the slider of Bottle Drive Unit does not come off.
D-1) Remove the ITB Unit referring [Removing the Bottle Drive Unit].
D-2) Check if the slider [a] of Bottle Drive Unit does not come off.
[Caution] When the ITB Unit comes off, check if the ITB Unit and the drum have scratches and then replace a part
if they do.
When the ITB Unit comes off, E025-0110/0210/0310/0410 or E025-0168/0268/0368/0468 occurs.
When the ITB Unit comes off, proceed on to Step D-3).
When the ITB Unit does not come off, perform another measure.
D-3) Remove the Bottle Drive Unit referring [Removing the Bottle Drive Unit].
Remove the Bottle Drive Unit (YM) when E025-0110/0210 or E025-0168/0268 occurs.
Remove the Bottle Drive Unit (CK) when E025-0310/0410 or E025-0368/0468 occurs.
D-4) Attach the slider which comes off to the Bottle Drive Unit.
[Caution]
- When the slider is attached, get the Bottle Drive Unit attachable referring "Attaching Bottle Drive Unit precaution" in the
[Removing the Bottle Drive Unit].
-After the attachment, check that the claw [a] of the slider is hung on the frame.
147
Summary of Contents for imageRUNNER ADVANCE C3330 Series
Page 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Page 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Page 105: ...If the symptom does not improve check other causes 100 ...
Page 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Page 144: ...139 ...
Page 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Page 197: ...Inner Finisher G1 EX QVA10470 192 ...