[Note] The FFC guide sheet (light blue) [1] is attached on the black FFC guide sheet in the same shape. If the FFC guide sheet
(light blue) is not attached, position the flat cable in parallel to the black FFC guide sheet just like the above and press while
making sure it does not become diagonal.
Reference] Refer to the photo below for the position [A] and [B].
[A]: Downward in a vertical direction from the inside of the frame [a]
[B]: Downward in a vertical direction from the inside of the frame in the center between [b] and [c]
c-9) Remove the liner from the double-sided tape located on the backside of the flat cable where folded and attach the doublesided
tape.
[Note] Be sure that the flat cable is straight against and is not loose from the FFC guide sheet.
c-10) With a scale, measure each of the distances [A] and [B] being from the upright potion of frame to the flat cable.