Chapter 2
2-29
2.7.8
After Replacing the
PickUp Motor/PickUp
Unit
0002-0460
CLC5100 / CLC4000
1) Place three or more A4 or LTR sheets of paper in
the cassette (upper, lower).
2) Select 'FUNC > PUPTMG' in service mode.
3) Execute 'PKADJU' three times.
A value near '186' will be indicated under 'DATA
A' and 'PUDTU'.
4) Press 'DSENDU' to write the adjustment data in
RAM.
5) Execute 'PKADJL' three times.
A value near '104' will be indicated under 'DATA
L' and 'PUDTL'.
6) Press 'DSENDL' to write the adjustment data in
RAM.
7) Write the value of 'PUDTU/L' on the service label.
8) End service mode.
2.7.9
Checking the
Environment
Measurement PCB
0002-0463
CLC5100 / CLC4000
The condition of the environment measurement PCB
and the environment sensor is checked using the
environment measurement checking tool (TKN0457)
and the sensor for the environment checking sensor
(TKN0456).
a. Checking the Environment Measurement PCB
1) Turn off the power switch.
2) Remove the multitray covers 1 and 2.
3) Remove the environment sensor from the
environment measurement PCB, and insert the
sensor for the environment measurement checking
sensor (TKN0457) in its place.
4) Turn on the power switch.
5) Set the meter to the 30 VDC range, and check to
make sure that the voltage of J11 (+) and J12 ()
on the environment measurement PCB is 24 V
±2.4V. If not, check the DC power supply PCB
(DCP1).
6) Start service mode, and select 'DISPLAY'.
7) Check the temperature and humidity on the
ANALOG screen.
BODY
ޓ
ºC ...... 25±5
BODY
ޓ
% ....... 40±10
8) Check to make sure that the reading is within
specification.
If not, go to step 9).
If the reading is as indicated, go to step 14).
9) Press the Reset key, and turn off the power switch.
10) Disconnect J1 of the environment measurement
PCB.
11) Turn on the power switch; start service mode, and
select 'DISPLAY'.
12) Check the temperature and humidity on the
ANALOG screen.
BODY
ޓ
ºC...... 25±5
BODY
ޓ
%....... 36±10
13) Check to make sure that the reading is as
indicated.
Reference
If the reading is not as indicated, suspect a fault in the
DC controller.
14) Press the Reset key.
15) Turn off the power switch.
16) Connect J1 of the environment measurement
PCB.
17) Remove the environment measurement sensor
from the environment measurement PCB, and
insert the environment sensor.
18) Install all covers.
b. Checking the Environment Sensor
1) Check the environment PCB.
2) Turn on the power switch, and leave it on for 5 min.
3) Start service mode, and select 'DISPLAY'.
4) Check the temperature and humidity on the
Summary of Contents for CLC5100 Series
Page 1: ...Jul 7 2004 Portable Manual CLC5100 Series ...
Page 2: ......
Page 6: ......
Page 11: ...Chapter 1 Maintenance and Inspection ...
Page 12: ......
Page 14: ......
Page 49: ...Chapter 2 Standards and Adjustments ...
Page 50: ......
Page 77: ...Chapter 2 2 25 F 2 48 5 Tighten the screw 2 for the guide plate View 3 A 2 1 View ...
Page 95: ...Chapter 3 Error Code ...
Page 96: ......
Page 97: ...Contents Contents 3 1 Error Code Details 3 1 3 1 1 Error Code Details 3 1 ...
Page 98: ......
Page 121: ...Chapter 4 User Mode Items ...
Page 122: ......
Page 123: ...Contents Contents 4 1 List of User Modes 4 1 ...
Page 124: ......
Page 127: ...Chapter 5 Service Mode ...
Page 128: ......
Page 130: ......
Page 223: ...Chapter 6 Outline of Components ...
Page 224: ......
Page 226: ......
Page 264: ...Chapter 6 ޓ 6 38 ...
Page 265: ...Chapter 7 System Construction ...
Page 266: ......
Page 268: ......
Page 282: ...Chapter 7 ޓ 7 14 ...
Page 283: ...Chapter 8 Upgrading ...
Page 284: ......
Page 285: ...Contents Contents 8 1 Outline of the Version Upgrade 8 1 ...
Page 286: ......
Page 288: ......
Page 289: ...Jul 7 2004 ...
Page 290: ......