Chapter 5
ޓ
5-60
2
Primary M charging assembly, grid M
output, auxiliary highvoltage Y (350
uA), developing bias MDC (370 V)
output
Transfer lifter DOWN, photosensitive drum
motor ON, preexposure ON, primary M output,
grid M output (500 V), auxiliary highvoltage
output M (350 uA), developing bias MDC (370
V) output IB (Waits for a stop command, or 60
sec.) Primary M output, grid M output (500 V),
auxiliary highvoltage output M (350 uA),
developing bias MDC (370 V) output OFF, pre
exposure OFF, photosensitive drum motor OFF
3
Primary Y charging assembly, grid Y
output, auxiliary highvoltage Y (350
uA), developing bias YDC (370 V)
output
Transfer lifter DOWN, photosensitive drum
motor ON, preexposure ON, primary Y output,
grid Y output (500 V), auxiliary highvoltage
output Y (350 uA), developing bias YDC (370
V) output IB (Waits for a stop command, or 60
sec.)Primary Y output, grid Y output (500 V),
auxiliary high voltage output Y (350 uA),
developing bias YDC (370 V) output OFF,
preexposure OFF, photosensitive drum motor
OFF
4
Primary K charging assembly, grid K
output, auxiliary highvoltage Y (350
uA), developing bias KDC (370 V)
output
Transfer lifter DOWN, photosensitive drum
motor ON, preexposure ON, primary K output,
grid K output (500 V), auxiliary highvoltage
output K (350 uA), developing bias
KDC (370 V) output IB (Waits for a stop
command, or 60 sec.)
Primary K output, grid K output (500 V),
auxiliary highvoltage output K (350 uA),
developing bias KDC (370 V) output OFF, pre
exposure OFF, photosensitive drum motor OFF
5
Primary Y/M/C/K primary charging
assembly, C/M/Y/K grid output, C/M/
Y/K transfer highvoltage, developing
bias C/M/Y/KDC 370 V) output,
internal static eliminator assembly,
separation charging assembly output
Transfer lifter UP, photosensitive drum motor
ON, preexposure ON, belt motor ON, transfer
blade ON
C/M/Y/K primary output, grid output (500 V),
developing bias DC (370 V) output, internal
static eliminator assembly output, separation
charging output, transfer charging output ON
(Waits for a stop command while the transfer belt
makes 10 rotations.)
Transfer charging output, internal static
eliminator assembly output, separation charging
output OFF, transfer blade OFF, post rotation
sequence
Details of SHV
No.
Highvoltage output
Control
Summary of Contents for CLC5100 Series
Page 1: ...Jul 7 2004 Portable Manual CLC5100 Series ...
Page 2: ......
Page 6: ......
Page 11: ...Chapter 1 Maintenance and Inspection ...
Page 12: ......
Page 14: ......
Page 49: ...Chapter 2 Standards and Adjustments ...
Page 50: ......
Page 77: ...Chapter 2 2 25 F 2 48 5 Tighten the screw 2 for the guide plate View 3 A 2 1 View ...
Page 95: ...Chapter 3 Error Code ...
Page 96: ......
Page 97: ...Contents Contents 3 1 Error Code Details 3 1 3 1 1 Error Code Details 3 1 ...
Page 98: ......
Page 121: ...Chapter 4 User Mode Items ...
Page 122: ......
Page 123: ...Contents Contents 4 1 List of User Modes 4 1 ...
Page 124: ......
Page 127: ...Chapter 5 Service Mode ...
Page 128: ......
Page 130: ......
Page 223: ...Chapter 6 Outline of Components ...
Page 224: ......
Page 226: ......
Page 264: ...Chapter 6 ޓ 6 38 ...
Page 265: ...Chapter 7 System Construction ...
Page 266: ......
Page 268: ......
Page 282: ...Chapter 7 ޓ 7 14 ...
Page 283: ...Chapter 8 Upgrading ...
Page 284: ......
Page 285: ...Contents Contents 8 1 Outline of the Version Upgrade 8 1 ...
Page 286: ......
Page 288: ......
Page 289: ...Jul 7 2004 ...
Page 290: ......