Chapter 1
1-33
F-1-12
5)Pull out the solenoid arm [5] with your fingers, open the shutter, and clean the sensor surface [6] with a blower
brush.
Do not wipe the sensor surface too strong. Wipe out toner as raking it.
F-1-13
6)Restore the solenoid arm in place with your fingers, and close the shutter.
7)After mounting the SALT sensor, execute the Service Mode FUNC>INSTALL>WINCLRY/M/C/K
(corresponding color).
1.4.8
How to Disassemble and Clean the SALT Sensor Unit
0002-8834
CLC5100 / CLC4000
1)Remove the second scoopup sheet [1] (two mounting screws) and the lower mylar [2] (two mounting screws)
respectively.
F-1-14
[2]
[1]
[2]
[1]
[3]
[1]
[2]
Summary of Contents for CLC5100 Series
Page 1: ...Jul 7 2004 Portable Manual CLC5100 Series ...
Page 2: ......
Page 6: ......
Page 11: ...Chapter 1 Maintenance and Inspection ...
Page 12: ......
Page 14: ......
Page 49: ...Chapter 2 Standards and Adjustments ...
Page 50: ......
Page 77: ...Chapter 2 2 25 F 2 48 5 Tighten the screw 2 for the guide plate View 3 A 2 1 View ...
Page 95: ...Chapter 3 Error Code ...
Page 96: ......
Page 97: ...Contents Contents 3 1 Error Code Details 3 1 3 1 1 Error Code Details 3 1 ...
Page 98: ......
Page 121: ...Chapter 4 User Mode Items ...
Page 122: ......
Page 123: ...Contents Contents 4 1 List of User Modes 4 1 ...
Page 124: ......
Page 127: ...Chapter 5 Service Mode ...
Page 128: ......
Page 130: ......
Page 223: ...Chapter 6 Outline of Components ...
Page 224: ......
Page 226: ......
Page 264: ...Chapter 6 ޓ 6 38 ...
Page 265: ...Chapter 7 System Construction ...
Page 266: ......
Page 268: ......
Page 282: ...Chapter 7 ޓ 7 14 ...
Page 283: ...Chapter 8 Upgrading ...
Page 284: ......
Page 285: ...Contents Contents 8 1 Outline of the Version Upgrade 8 1 ...
Page 286: ......
Page 288: ......
Page 289: ...Jul 7 2004 ...
Page 290: ......