Chapter 3
3-6
xx4C
Backup data (DC controller PCB; error)
Be sure to execute RAM clear, and enter the
value recorded on the service label.
Initial settings may be missing.
During copying sequence, the average value after
sampling of the following values is 512 or lower: SGNL
SC, SGNLSM, SGNLSY; or, the value of SGNLS
K is 102 or lower.
xx4D
During copying sequence, the average value after
sampling of the following values is 336 or lower: REF
SC, REFSM, REFSY; or, the value of REFSK is
464 or lower.
xx4F
SALT sensor (fault)
The value of 'SGNLSC/M/Y/K', which has been
obtained by averaging samplings during copying
sequence is 1008 or more.
xx50
SALT sensor (faulty)
Stirring (developer inside developing
assembly; faulty)
Stray light (to sensor; no cover, front cover
open)
Photosensitive drum (deterioration)
When setting initial data (upon installation, for example),
the gain cannot be set (i.e., no change is noted in the
value of SGNL between GAIN: 20H and GAIN: E0).
0455
An appropriate patch cannot be obtained when setting
initial data (e.g., at time of installation).
xx60
SALT sensor (dirt on window, damage)
Photosensitive drum (dirt; cleaning failure)
During multiple initial rotation (at poweron, for
example), the window cleaning correction value is 60%
or lower.
xx70
During multiple initial rotation (at poweron, for
example), the window cleaning correction value is 140%
or lower.
xx80
Backup data (DC controller PCB; error)
Be sure to execute RAM clear, and enter the
value recorded on the service label.
Initial settings may be missing.
During copying sequence, the initial setting for the
following is 848 or higher because of an error in the
memory backup data: SGNLSC, SGNLSM, SGNL
SY; or, the value of SGNLSK is 352 or higher.
xx81
During copying sequence, the initial setting for the
following is 848 or higher because of an error in the
memory backup data: REFSC, REFSM, REFSY;
or, the value of REFSK is 544 or higher.
xx82
Backup data (DC controller PCB; error)
Be sure to execute RAM clear, and enter the
value recorded on the service label.
Initial settings may be missing.
During copying sequence, the value of the following is
255 because of an error in the memory backup data:
SIGGSC, SIGGSM, SIGGSY, SIGGSK
xx85
During copying sequence, the initial setting for the
following is 512 or lower because of an error in the
memory backup data: SGNLSC, SGNLSM, SGNL
SY; or, the value of SGNLSK is 144 or lower.
Code
Cause
Description
Summary of Contents for CLC5100 Series
Page 1: ...Jul 7 2004 Portable Manual CLC5100 Series ...
Page 2: ......
Page 6: ......
Page 11: ...Chapter 1 Maintenance and Inspection ...
Page 12: ......
Page 14: ......
Page 49: ...Chapter 2 Standards and Adjustments ...
Page 50: ......
Page 77: ...Chapter 2 2 25 F 2 48 5 Tighten the screw 2 for the guide plate View 3 A 2 1 View ...
Page 95: ...Chapter 3 Error Code ...
Page 96: ......
Page 97: ...Contents Contents 3 1 Error Code Details 3 1 3 1 1 Error Code Details 3 1 ...
Page 98: ......
Page 121: ...Chapter 4 User Mode Items ...
Page 122: ......
Page 123: ...Contents Contents 4 1 List of User Modes 4 1 ...
Page 124: ......
Page 127: ...Chapter 5 Service Mode ...
Page 128: ......
Page 130: ......
Page 223: ...Chapter 6 Outline of Components ...
Page 224: ......
Page 226: ......
Page 264: ...Chapter 6 ޓ 6 38 ...
Page 265: ...Chapter 7 System Construction ...
Page 266: ......
Page 268: ......
Page 282: ...Chapter 7 ޓ 7 14 ...
Page 283: ...Chapter 8 Upgrading ...
Page 284: ......
Page 285: ...Contents Contents 8 1 Outline of the Version Upgrade 8 1 ...
Page 286: ......
Page 288: ......
Page 289: ...Jul 7 2004 ...
Page 290: ......