prOGrAMMATION
web Server item F452
The Web Server (F452) is programmed with a software called TiF452 whose
installation and configuration are described in detail in the user manual in
the CD supplied with the devices.
The following main parameters must be configured:
-
IP address: This is the address for the communication of packets over the
Internet needed to identify the Web Server. This address must be static
(fixed); if static (fixed) addresses are not available, contact your network
administrator. The “Subnet Mask” parameter, typical of networks which
use the TCP/IP protocol, must be set together with the IP address.
In this
case also, contact your network administrator for the assignment of this
parameter.
-
login and password: This is the identification name (login) and password
for the connection. Those entered as default in the factory are “BTicino”,
which the user can modify and personalise.
-
e-mail address: This is the address for sending electronic mail warnings
of intrusion and auxiliary alarms. The IP address of the SMTP (Simple Mail
Transfer Protocol) Server must be set and if necessary that of the mail
Router.
-
Web pages: For the management and control, via pushbuttons which can
be personalised, of the devices of the Lighting, Automation, Burglar-alarm,
Energy Management and CCTV systems via remote PC with Internet Explorer
5.5 browser program or similar.
TiServer program window
where the lights page is
defined