MY HOME cOntROL
technical
GUiDe
67
configurAtion
table
Function
Type of
Position
Position
Position
Position
Position
control
A
PL1/PF1
PL2/PF2
PL3/PF3
PL4/PF4
cyclical ON-OFF
Light point
1 to 9
1 to 9
1 to 9
1 to 9
1 to 9
for short press
in the room
+ adjustment (dimmer)
indicated in R
cyclical ON-OFF
Room
1 to 9
AMB
AMB
AMB
AMB
control
2)
Rolling shutter
Light point
1 to 9
1 to 9
1 to 9
up-down
1)
in the room
1 to 9
1 to 9
indicated in A
1 to 9
1 to 9
1 to 9
1 to 9
1 to 9
1 to 9
1 to 9
1 to 9
Monostable
Room
1 to 9
M
M
rolling shutter
control
2)
M
M
up-down
1)
M
M
M
M
M
M
M
M
Rolling shutter
Room
1 to 9
up-down
control
2)
to end of stroke
1)
ON control
Room
1 to 9
ON
ON
ON
ON
control
2)
OFF control
Room
1 to 9
OFF
OFF
OFF
OFF
control
2)
Example 1
If on the receiver positions PL2 and PL3 have configurator 7, the remote
control operates double actuator 7 of the room indicated in A, raising the
rolling shutters with pushbutton 2 and lowering them with pushbutton 3.
rear view
This mode lets the user associate generic controls (ON/OFF, UP/DOWN)
intended for single loads or double loads with the remote control keys.
The correspondence between the remote control keys and the loads
controlled is determined in the installation phase by the configuration of
positions A and PL 1 to PL 4 of the IR receiver, as shown in the table below.
The following can be associated with the remote control pushbuttons:
- Point-point controls, i.e. intended for single or double loads (rolling shutter
motor) whose address is specified by configurator 1 to 9 in positions PL 1
to PL 4. The various operating modes are determined by the association of
the configurators with the PL positions.
- Controls intended for actuators for single and double loads belonging to the
room defined with configurator 1 to 9 in position A. In this case the operating
modes are defined by the configurators marked by the graphics of the
function performed, inserted in positions PL 1 to 4.
addresses/
operating mode
definition of
channels 1 to 16 of
the remote control
Example 2
If on the receiver positions PL2 and PL3 have configurator and position A has
configurator 2, the remote control operates all the actuators in room 2, raising
the rolling shutters with pushbutton 2 and lowering them with pushbutton 3.
1) The two PL positions must have the same configurator. The UP control is associated
with the first PL position and the DOWN control with the second PL position.
2) The control is intended for devices belonging to the room indicated in A.
mode "A" (remote control) m = 1 to 4