MY HOME cOntROL
technical
GUiDe
61
configurAtion
Device with three independent controls.
Can drive actuators for single loads with 1 relay or actuators with 2
interlocked relays and send controls for the management of advanced
devices if configured with CEN configurator.
On the back the device has three distinct A and PL positions which refer to
three keys on the front part.
Going from left to right the three front keys correspond to control 1 (A1,
PL1), control 2 (A2, PL2) and control 3 (A3, PL3).
The following table lists all the operating modes with the configurator in
position
M
.
front view
upper
pushbuttons
lower
pushbuttons
LED
control 1
control 2
rear view
control 3
BUS
PL1
A1
M
SPE
AUX
PL
A
L4651/2
M
SPE
AUX
PL
A
PL1
A1
A2
PL2
M
A3
PL3
L4652/3
L/N4681
PL
A
M
M
G1
G2
PL
A
L4671/1
M
G
PL
A
L4671/2
L/N4688
SPE
PL2
M
PL1
A1
SPE
PL2
M
position M
Configurator value in position M
Key covers used/function
no configurator
cyclical ON-OFF
NOTE: if the control is associated with a dimmer actuator item H/L4678 item H/
L4674 with operating modes cyclical ON-OFF, ON (upper key) and OFF (lower key)
the brightness can also be adjusted.
Configurator value in position M
Key covers used/function
2
ON-OFF
up-down
cyclic
5
ON-OFF
up-down
cyclic
monostable
8
ON-OFF
ON (upper key)
cyclic
OFF (lower key)
Configurator value in position M
Key covers used/function
1
ON-OFF
up-down
cyclic
4
ON-OFF
up-down
cyclic
monostable
7
ON-OFF
ON (upper key)
cyclic
OFF (lower key)
Configurator value in position M
Key covers used/function
3
up-down
6
up-down monostable
9
ON (upper key)
OFF (lower key)
CEN
enabling the T1-T2-T3 (upper) and
T4-T5-T6 (lower) keys to manage
scenarios of the programmer
MH200.
*
NOtE (*):
Do not configure positions A2, PL2 and A3, PL3.
control item H/l4652/3
and item Am5832/3
operAting mode