94
my Home - control
To exceed the limit of actuators which can be installed several systems can
be connected on an automation bus by means of SCS/SCS interfaces. The
bus on which all the others are connected performs the function of “private
system WitH logicAl expAnsion
riser”.
In this type of system the scenario Programmer can only be connected to the
“private riser”, but the scenarios which can be produced can concern all the
connected systems.
A/PL =11-99
A/PL =11-99
A/PL =11-99
I1 = -
I2 = -
I3 =
I4 = 4
M = 2
I1 = -
I2 = -
I3 =
I4 = 3
M = 2
Private
riser
F422
I1 = -
I2 = -
I3 =
I4 = 2
M = 2
F422
F422
M =
CEN
M =
CEN
Local
BUS
Local
BUS
Local
BUS
0
0
0
2
2
2
2
2
2
(*)
NOTE
(*)
: if so designed, the control devices configured with mode M = CEN
can be connected at any point of the system.
tecHnicAl feAtures
scenario programmer item mH200