48
my Home - control
ActuAtors: Address And type of control
To understand the addressing logical it is useful to define some terms which
will occur frequently in this text.
Room (A)
Set of devices belonging to a logical area (in a home, for example, the living
room, the bedroom, etc.).
Light Point (PL)
Numeric identification of the single actuators inside the Room.
Group (G)
Set of devices also belonging to different rooms but which must be
controlled at the same time (e.g. the rolling shutters of the North side of the
home, the lighting of the day area, etc.).
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
40,
C?0$
40,
C?0%
40,
C?0,
40,
C?0$
40,
C?0%
40,
C?0,
6bageb_f
4VghTgbef
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
40$
C?0$
40$
C?0%
40$
C?0,
40$
C?0$
40$
C?0%
40$
C?0,
:ebhc$
:ebhc,
A = GR
PL = 1
40$
C?0$
40,
C?0%
Ebb`,
Ebb`%
Ebb`+
Ebb`&
Ebb`'
Ebb`(
Ebb`)
Ebb`*
Ebb`$
$gb`Tk,
$gb`Tk,
$gb`Tk,
Up to 9 room addresses can be
managed in one system.
For each room up to 9 addresses can be
managed for each actuator.
To these addresses are added any
belonging to one or more groups.
Actuator address
The address of each actuator is defined uniquely by assigning the numeric
configurators 1 to 9 in positions A (Room) and PL (Light Point inside the
Room).
A maximum of 9 addresses can be defined for each room; a maximum of 9
rooms can be defined in a system.
The group of belonging is defined by inserting a third numeric configurator in
the housing identified with G (Group).
Some actuators have several G positions (G1, G2 and G3) as they can belong
to several different groups at the same time.
Example:
The actuator configured with A = 1, PL = 3 and G = 4 is device 3 of
room 1 belonging to group 4.
For special applications such as extended systems in houses or service/
industrial rooms, where the use of many devices may exceed the
configuration limits mentioned above (9 addresses for each of the 9 rooms
planned), interface item F422 can be used, configured in the “logical
expansion” mode.
This mode can make an extension system made up of several individual
systems, each of which may thus use all the 81 addresses, connected
together on a single bus with riser function. A typical use may be the house
distributed over several floors: a system can be made for each floor and they
can be connected by means of interface item F422.
logicAl extension
configurAtion