MY HOME cOntROL
technical
GUiDe
71
configurAtion
Single function
If pushbuttons or switches are connected to the contacts, the interface can
be assimilated to a control for double loads equipped with two one-module
key covers. In this case the ON, OFF or adjustment function, for two separate
loads, can be assigned to each key cover.
Double function
If a two-way switch is connected to the contacts, the interface can be
assimilated to a control for double loads equipped with a double-function
two-module key cover. In this case the ON, OFF, rolling shutter UP-DOWN for
one load, can be assigned to the key cover.
or
Devices for one double-function load
(two-way switch, interlocked switches, etc.)
1
1
BUS
PL1
PL2
COM
Devices for two separate loads
(switches, pushbuttons, etc.)
1
2
PL1
PL2
COM
BUS
is the same as
is the same as
is the same as
is the same as
PL1
PL2
PL2
PL1
COM