82
my Home - control
configurAtion
interface scs-scs item f422
Positioning the devices in the system control configuration and logic
In configuring the global Automation system, remember that:
1. each system connected to the common riser may use all the 81 addresses
provided (9 light points for 9 Rooms) apart from the address of interface
item F422 which will be assigned in positions I3 and I4.
control for extended systems item H/L4655
Using this device in a system with logical expansion enables you to send,
from a single system connected to the main riser, any type of control (room
control, point-point control, etc.) directed to actuators situated in the riser
itself or in another system connected with interface item F422.
This is made possible by configuring the address of the interface item F422
- used for transferring the information - in the cross control device. For more
information, please refer to chapter “Configuration” (control item H/L4655).
Bus 2
Bus 1
Control unit with
telephone dialling device
item 3500N
item 3500GSM
Special control
item L4651/2
Single
Automation
system
Main
riser
Interface
F422
Type of control
POINT - POINT
ROOM
GROUP
GENERAL
AUXILIARY
ENERGY
MANAGEMENT
SINGLE INSTALLATION
MAIN RISER
2. The common riser must be made up of an Automation system in which
the Energy management Control unit and the control unit with dialling
device item 3500 can be installed as well as the control devices and
actuators.
3. Interface F422 allows the transit of the controls between the individual
systems and the common riser as follows:
Example: the Point-Point control and the Room control are only possible
between control devices and actuators belonging to each individual system
or to the common riser. The interface does not in fact allow the control to
transit from an individual system to the riser and vice versa.
MOD = 2