2-48
Confidential
4.2.5
Recording paper jam
■
Paper tray jam
<User Check>
- Check if the recording paper is loaded correctly in the Paper tray.
- Adjust the paper guide to match the recording paper size.
- Check if the recording paper loaded is smaller than the specified size.
- Check if the recording paper's thickness is within specifications.
- Check if too much recording paper is loaded in the Paper tray.
- Clean the Paper feed roller.
- Check that the Jam clear cover is securely closed.
- Check if there is no curling or bending in the recording paper.
Step
Cause
Solution
1
Foreign materials in the
recording paper feeding path
Remove foreign materials.
2
Jam clear cover not mounted
in place
Reattach the Jam clear cover.
3
CR guide rail not properly
attached
Reattach the CR guide rail.
4
Platen not mounted in place
Reattach the Platen ASSY.
5
Paper feeding path parts out of
place
Set the paper feeding path parts into place.
6
Jam clear cover defective
Replace the Jam clear cover.
7
Paper tray defective
Replace the Paper tray.
8
Paper width sensor defective
Replace the Carriage PCB.
9
Platen defective
Replace the Platen ASSY.
10
Paper feed motor defective
Replace the Paper feed motor.
11
Registration sensor defective
Replace the Registration sensor PCB ASSY.
12
Main PCB defective
Replace the Main PCB ASSY.
Summary of Contents for DCP Series
Page 111: ...3 3 Confidential 2 PACKING For Ink Cartridge Model 3_002L ...
Page 112: ...3 4 Confidential For Ink Tank Model 3_002L 1 ...
Page 119: ...3 11 Confidential 2 CIS flat cable 3_006L CIS flat cable Cable guide Cable guide Flat core ...
Page 234: ...5 12 Confidential Scanning Compensation Data List ...
Page 236: ...5 14 Confidential Test Pattern ...
Page 240: ...5 18 Confidential Configuration List ...
Page 256: ...5 34 Confidential pfadj1 Pattern pfadj2 Pattern ...
Page 264: ...5 42 Confidential Margin Check Pattern ...
Page 294: ...6 3 Confidential Power supply PCB 100 V series ...
Page 295: ...6 4 Confidential Power supply PCB 200 V series ...
Page 309: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...