3-23
Confidential
9
DISASSEMBLY PROCEDURE
9.1
Preparations
[1]
Transferring Received FAX Data
When the product needs to be repaired, received FAX data if left in the unit for repair are
lost when the Power cord is unplugged from the electrical outlet.
To prevent data loss, you can transfer remaining fax files inside the unit to another fax
machine or PC. The service personnel must instruct the user on the phone to follow the
procedure below and guide the user on how to transfer data.
Note
The number of fax data files that can be transferred at a time is 99. To transfer more
than 100 fax data files, the user needs to perform the procedure below as many times as
necessary.
Tip
If there are both color and monochrome files to be transferred, the monochrome data
will be transferred first. If the receiving machine does not support color data, the sending
machine will not be able to transfer color data and will receive an error.
Transferring fax data to another fax machine
■
Operating Procedure
(1) Press the [Stop/Exit] key to close the error message (if displayed).
(2) Press the [Menu] key.
(3) Press [ ] or [ ] to choose "Service". Press [OK] key.
(4) Press [ ] or [ ] to choose "Data Transfer". Press [OK] key.
(5) Press [ ] or [ ] to choose "Fax Transfer". Press [OK] key.
(6) If a fax number entry screen appears, there are fax messages in the memory. Enter
the fax number to which the fax messages would be forwarded.
(7) Press the [Black Start] key.
Summary of Contents for DCP Series
Page 111: ...3 3 Confidential 2 PACKING For Ink Cartridge Model 3_002L ...
Page 112: ...3 4 Confidential For Ink Tank Model 3_002L 1 ...
Page 119: ...3 11 Confidential 2 CIS flat cable 3_006L CIS flat cable Cable guide Cable guide Flat core ...
Page 234: ...5 12 Confidential Scanning Compensation Data List ...
Page 236: ...5 14 Confidential Test Pattern ...
Page 240: ...5 18 Confidential Configuration List ...
Page 256: ...5 34 Confidential pfadj1 Pattern pfadj2 Pattern ...
Page 264: ...5 42 Confidential Margin Check Pattern ...
Page 294: ...6 3 Confidential Power supply PCB 100 V series ...
Page 295: ...6 4 Confidential Power supply PCB 200 V series ...
Page 309: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...