5-44
Confidential
1.4.23 Traveling Speed Check of Head/Carriage Unit (Maintenance mode 69)
<Function>
This function checks whether the traveling speed of the Head/carriage unit is within the
specified range.
<Operating Procedure>
(1) Enter [6] and [9] in the initial stage of the maintenance mode.
The machine shows "CR AGING" on the LCD and starts checking the traveling speed
of the Head/carriage unit.
In each of travel speeds of 43.3, 26.7 and 21.7 inches/second (ips), the machine
checks whether the maximum and minimum traveling speeds of the Head/carriage unit
are within the specified range.
- If the maximum and minimum speeds in all of the three traveling speeds are within
the specified range, "430 270 210" appears on the LCD.
- If any one is out of the range, the machine shows some message, e.g., "430 270
21X," on the LCD. This sample message indicates that the speed variation is within
the allowable range when the Head/carriage unit travels at 43.3 and 26.7 inches/
second; however, it is out of the range at 21.7 inches/second.
(2) Press [Stop] or [X] to return the machine to the initial stage of the maintenance mode.
Summary of Contents for DCP Series
Page 111: ...3 3 Confidential 2 PACKING For Ink Cartridge Model 3_002L ...
Page 112: ...3 4 Confidential For Ink Tank Model 3_002L 1 ...
Page 119: ...3 11 Confidential 2 CIS flat cable 3_006L CIS flat cable Cable guide Cable guide Flat core ...
Page 234: ...5 12 Confidential Scanning Compensation Data List ...
Page 236: ...5 14 Confidential Test Pattern ...
Page 240: ...5 18 Confidential Configuration List ...
Page 256: ...5 34 Confidential pfadj1 Pattern pfadj2 Pattern ...
Page 264: ...5 42 Confidential Margin Check Pattern ...
Page 294: ...6 3 Confidential Power supply PCB 100 V series ...
Page 295: ...6 4 Confidential Power supply PCB 200 V series ...
Page 309: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...