3-32
Confidential
(10) Unlock the connector on the Carriage PCB and disconnect the Head flat cable.
Note
After disconnecting the flat cable, check that each cable is not damaged at its end or
short-circuited. When connecting the flat cable, do not insert it at an angle. Lock the
connector, after confirming that the cable is not at an angle.
(11) Release the spring lock and slightly raise the Carriage PCB. Next, remove the
Carriage flat cable from the Cable guide of the Head/carriage unit (refer to the
illustration in
) and release the boss from the opening in the film (refer to the
illustration below).
(12) Take the Carriage PCB ASSY out of the Head/carriage unit and put it on the Upper
cover in front of the Head/carriage unit.
(3_026L)
Head/carriage unit
Lock spring
Carriage PCB ASSY
Head flat cable
Carriage flat cable
Remove by pulling the lock
Carriage PCB ASSY
Head/carriage unit
Upper cover
Boss
Head flat cable
Opening
Film
Connector
Summary of Contents for DCP Series
Page 111: ...3 3 Confidential 2 PACKING For Ink Cartridge Model 3_002L ...
Page 112: ...3 4 Confidential For Ink Tank Model 3_002L 1 ...
Page 119: ...3 11 Confidential 2 CIS flat cable 3_006L CIS flat cable Cable guide Cable guide Flat core ...
Page 234: ...5 12 Confidential Scanning Compensation Data List ...
Page 236: ...5 14 Confidential Test Pattern ...
Page 240: ...5 18 Confidential Configuration List ...
Page 256: ...5 34 Confidential pfadj1 Pattern pfadj2 Pattern ...
Page 264: ...5 42 Confidential Margin Check Pattern ...
Page 294: ...6 3 Confidential Power supply PCB 100 V series ...
Page 295: ...6 4 Confidential Power supply PCB 200 V series ...
Page 309: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...