2-33
Confidential
■
Error Code 50
Failed to detect that the Purge cam switch is turned ON.
Error Code 52
Cannot detect the home position of the Purge cam. (Failed to detect the longest OFF
status interval of the maintenance cam)
■
Error Code 5A
Abnormal stopping of the Purge cam.
Error Code 5B
The Maintenance unit pump abnormally stopped during exhaust/intake.
Error Code 5D
Overcurrent protection was activated in the driver IC during Purge cam operation.
Error Code 5E
Overcurrent protection was activated in the driver IC during Maintenance unit pump
operation.
Unable to print 50
LCD
Unable to print 52
LCD
Step
Cause
Solution
1
Foreign materials in the
Maintenance unit part
Remove foreign materials.
2
Purge cam sensor harness
connection failure
Reconnect the Purge cam sensor harness.
3
Purge cam sensor defective
Replace the Maintenance unit.
4
Main PCB defective
Replace the Main PCB ASSY.
Unable to print 5A
LCD
Unable to print 5B
LCD
Unable to print 5D
LCD
Unable to print 5E
LCD
Step
Cause
Solution
1
Foreign materials in the
Maintenance unit part
Remove foreign materials.
2
Maintenance unit defective
Replace the Maintenance unit.
3
Main PCB defective
Replace the Main PCB ASSY.
Summary of Contents for DCP Series
Page 111: ...3 3 Confidential 2 PACKING For Ink Cartridge Model 3_002L ...
Page 112: ...3 4 Confidential For Ink Tank Model 3_002L 1 ...
Page 119: ...3 11 Confidential 2 CIS flat cable 3_006L CIS flat cable Cable guide Cable guide Flat core ...
Page 234: ...5 12 Confidential Scanning Compensation Data List ...
Page 236: ...5 14 Confidential Test Pattern ...
Page 240: ...5 18 Confidential Configuration List ...
Page 256: ...5 34 Confidential pfadj1 Pattern pfadj2 Pattern ...
Page 264: ...5 42 Confidential Margin Check Pattern ...
Page 294: ...6 3 Confidential Power supply PCB 100 V series ...
Page 295: ...6 4 Confidential Power supply PCB 200 V series ...
Page 309: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...