Macro Recording Timeout
This option defines the timeout of the macro recording process. (Possible values are 01 – 99
seconds.) The timeout defines the time after which the macro recording process is cancelled
due to inactivity of the user.
Play Pause Time
This option defines the speed of the macro playing process. If a user wants to observe the
macro playing process more closely, it can be adjusted to display the single operations longer.
The default setting is 03=300ms and can be adjusted to 01=100ms, 02=200ms and so on.
Code inside Macro Enable
This option enables/disables the code inside a macro. This function is relevant only if the
macro without code function is disabled.
If this function is enabled, a code will be recorded during the macro recording process and
will be executed during the macro playing process. This means that a user switch is possible
when the macro playing function is executed.
If this function is disabled, there will be no code recorded during the macro recording process
and the operation assigned to the macro will be executed without a code. This means that
there is no user switch possible in the macro playing function and that the user who is
executing the macro playing function is also executing the operation assigned to the macro.
Code Reporting
The following codes are reported when an alarm occurs:
Installer
Report = 0
User 1 - 250
Report = 1 - 250
A-Link
Report = 251
Phone arm
Report = 252
Single-Button arm / disarm
Report = 253
Key switch arm / disarm
Report = 254
Zones
Add / Delete Zone
When adding or changing a zone, it is required to select the area, the zone functions and the
module of the zone source, based on zone numbers.
When the zone is specified as “0”, i.e. the zone is not used; any address set on the zone
function and module selection is invalid.
Zone Module
The AMAX panel supports onboard zones, keypad zones, AMAX 3000 / 3000 BE / 4000, and
DX2010 zones and RF zones. For each zone number a certain range of selectable modules is
defined.
Zone Function
When selecting the zone function via text keypad, the zone type that has been selected for the
zone function of each zone is displayed.
The following zone types can be selected for the zone function of each zone.
Zone Function Option
Description
Zone Type
00
Not used
01
Instant
6.2.6
6.3
6.3.1
AMAX panel
Settings | en