The panel complies with the following standards:
RTC 50131-3 NF3248H58-2011 V1
RTC 50131-6 NF3248H58-2011 V1
Reference:
NF324 H58 2.5
Option 3: Grade 2 (European EN standards) + RTC
Certification Number:
1223400001
AMAX 4000
1223400002
AMAX 3000
1223400002
AMAX 2100
Prerequisites for an NFa2p conform installation
For an NFa2p conform installation it is necessary to seal the enclosure either with a sealing
wire or an adhesive seal.
For further information about the sealing wire and the adhesive seal, please reverse directly to
your local Bosch contact.
Sealing the enclosure with a sealing wire
1.
Open the pre-opened hole which is on the right of the enclosure.
2.
Pass the sealing wire through this hole, and bring the two wires in the corresponding hole
of the enclosure door.
3.
Seal the sealing lead as near as possible from the enclosure.