Siren Programming
Option
Address
Default
Beep for warning devices (0 = disabled, 1 = enabled)
1600
1
Internal siren beep as indication (0 = disabled, 1 =
enabled)
1611
0
Silence warning device when disarmed (0 = disabled, 1 =
enabled)
1605
1
RF Device Programming
RF Options
Option
Address
Default
Printer functionality (0 = disabled, 1= enabled)
0991
0
RF receiver functionality (0 = disabled, 1= enabled)
0948
0
RF supervision interval (0 = disabled, 1 = 20 min, 2 = 1h, 3
= 2h, 4 = 4h, 5 = 12 h, 6 = 24h)
0949
4
EN=2
RF jam detect level (00 - 15, 00 = disabled, 01 = most
sensitive, 15 = least sensitive)
0950
12
RF device low level battery resound (0 = disabled, 1 = 4h,
2 = 24h)
0951
2
Siren beep arm/disarm (RF keyfob) (0 = disabled, 1=
enabled)
0952
1
Keyfob panic option (0 = no alarm, 1 = silent alarm, 2 =
sound alarm)
0953
0
RF missing as alarm (0 = disabled, 1= enabled)
0954
1
Wireless Zone RFID
RFID for
wireless
zone no.
Address
Default
(ten
digits, 15
= not in
use)
RFID for
wireless
zone no
Address
Default
(ten
digits, 15
= not in
use)
1
5256 – 5265
15
33
5576 – 5585
15
2
5266 – 5275
15
34
5586 – 5595
15
3
5276 – 5285
15
35
5596 – 5605
15
4
5286 – 5295
15
36
5606 – 5615
15
5
5296 – 5305
15
37
5616 – 5625
15
8.6.2
8.7
AMAX panel
Address Programming | en 139
Bosch Sicherheitssysteme GmbH
Installation Manual