Digit required
Number to program via
address programming
Button to press via installer
menu programming
0 - 9
0 - 9
0 - 9
*
11
* 1
#
12
* 2
4 sec pause
13
* 3
Terminal
15
Not required
How to program an IP address and port:
1.
Program an IP address with 17 digits: digits 1 - 12 for the IP address and 13 - 17 for the
port.
2.
Use no punctuation in the IP address.
3.
If any unit of the IP address has less than 3 digits, use 0 to fulfill the data in the higher
bits.
4.
The remaining 5 digits program the port. Port number ranges from 0-65535.
5.
If a port number has less than 5 digits, use 0 to fulfill the data.
Example
4
To program the IP address “10.16.1.222:80”, enter the following sequence into the
correspondent address:
[0 1 0 0 1 6 0 0 1 2 2 2 0 0 0 8 0]
Notice!
Programming option anti-replay, acknowledge wait time, and pulse interval time are only used
in Conettix IP.
Telephone number for Receiver 1 – 4 / IP Address and Port
When the corresponding data format for above programming address is a network
communication format, it is explained as an IP address, and port. For a non network format, it
is explained as a telephone number.
The AMAX panel contacts the telephone number / IP Address of the central monitoring station
in order to transmit a report. If the contact is successful, the relevant information is
transmitted, and the communicator returns to standby mode.
Contact your monitoring station for the correct telephone number / IP address before you
program these addresses.
Receiver subscriber ID Number
Receiver 1 - 4 subscriber ID Number
The subscriber ID number is transmitted to identify the calling AMAX panel.
Digits from 0 – 9 and letters from B – F are supported
How to program a subscriber ID number:
1.
Enter the subscriber ID number in the six addresses provided for each destination.
2.
If a subscriber ID number has less than 6 digits, use 0 to full fill the data in the higher
bits.
Example
4
Program subscriber ID number as 4729 in six addresses: [0 0 4 7 2 9]
AMAX panel