3.
STAY Arm:
–
This zone will be ignored and performed as disarm.
–
Refer to Keypad Indicators to see how the zone is displayed during exit time.
13 – 24 Hour
The 24-hour zone type performs as described below:
1.
Disarm:
–
Zone normal - no alarm / no report
–
Zone triggered - alarm / report
2.
AWAY Arm:
–
Zone normal - no alarm / no report
–
Zone triggered - alarm / report
–
Zone triggered - during exit time - alarm / report
–
Zone triggered - during entry time - alarm / report
3.
STAY Arm: same as AWAY arm performance.
–
A 24 - hour zone does not send a restore report until the zone is restored.
14 – Key AWAY Toggle
The key switch AWAY toggle zone type performs as described below:
1.
Disarm:
–
Zone normal - no action
–
Zone triggered - activate AWAY arm / report
2.
AWAY Arm:
–
Zone normal - no action
–
Zone triggered - activate disarm / report
3.
STAY Arm: same as AWAY arm performance
This zone will ignore all other programming items, such as bypass, forcing arm.
When the system is armed in this mode, the keypad activates two beeps and report sent is by
user code 254.
15 – Key AWAY on/off
The key switch AWAY on / off zone type performs as described below:
1.
Disarm:
–
Zone normal - no action
–
Zone triggered - activate AWAY arm / report
2.
AWAY Arm:
–
Zone normal - activate disarm / report
–
Zone triggered - no action
3.
STAY Arm: same as AWAY arm performance
Wiring diagram for key-switch zone: short for arm. The momentary time is capable of lasting
Minimum 300ms.
COM
Zone
Wiring diagram for key-switch zone: open for arm. The momentary time is capable of lasting
Minimum 300ms.
58
en | Settings
AMAX panel
2015.05 | 06 | F.01U.309.277
Installation Manual