![Bosch AMAX 4000 Installation Manual Download Page 123](http://html.mh-extra.com/html/bosch/amax-4000/amax-4000_installation-manual_39247123.webp)
Zone Programming
Add/Delete Zone Programming
AMAX 4000 supports up to 64 zones, 16 keypads and 16 areas.
AMAX 3000 / 3000 BE support up to 32 zones, 8 keypads and 8 areas.
AMAX 2100 supports up to 8 zones, 4 keypads and 2 areas.
Zone Module Selection
Zone no.
Address
Default
Zone no.
Address
Default
01
1432
0
05
1436
0
02
1433
0
06
1437
0
03
1434
0
07
1438
0
04
1435
0
08
1439
0
Value range: 0 = onboard zone, 3 = RF all, 4 = RF RFGB glassbreak, 5 = RF RFUN no magnet,
15 = not used
Zone no.
Address
Default
Zone no.
Address
Default
09
1440
0
13
1444
0
10
1441
0
14
1445
0
11
1442
0
15
1446
0
12
1443
0
16
1447
0
Value range: 0 = onboard zone (AMAX 4000), 2 = DX2010 zone, 3 = RF all, 4 = RF RFGB
glassbreak, 5 = RF RFUN no magnet, 15 = not used
Zone no.
Address
Default
Zone no.
Address
Default
17
1448
15
25
1456
15
18
1449
15
26
1457
15
19
1450
15
27
1458
15
20
1451
15
28
1459
15
21
1452
15
29
1460
15
22
1453
15
30
1461
15
23
1454
15
31
1462
15
24
1455
15
32
1463
15
Value range: 1 = Keypad zone (zones 17 to 32 are dedicated to keypad 1 to 16), 2 = DX2010
zone, 3 = RF all, 4 = RF RFGB glassbreak, 5 = RF RFUN no magnet, 15 = not used
Zone no.
Address
Default
Zone no.
Address
Default
33
1464
0
49
1480
0
34
1465
0
50
1481
0
8.3
8.3.1
AMAX panel
Address Programming | en 123
Bosch Sicherheitssysteme GmbH
Installation Manual
2015.05 | 06 | F.01U.309.277