RF Devices
RF Options
RF Receiver Functionality
Enables or disables RF receiver functionality.
RF Supervision Interval
Disables or defines RF Supervision Interval. The interval can be set to 1, 2, 4, 12, 24, or 25
hours.
RF Jam Detect Level
Defines RF jam detect level. The range is 00 - 15:
–
00 = disabled
–
01 = most sensitive
–
15 = least sensitive
RF Device Low Level Battery Resound
Disables or sets the interval for keypad acoustic indication of RF device low level battery fault.
Siren Beep Arm / Disarm (RF Keyfob)
Enables or disables keypad acoustic indication on arm / disarm.
Keyfob Panic Option
Defines the behavior when keyfob panic button is pressed. The option can be set to no alarm,
silent alarm, or non silent alarm.
RF Devices / User
RF User
Keyfobs are designed for arming and disarming the system remotely, trigger a panic alarm, or
for additional control functionality.
To operate the buttons, press and hold either button for at least one sec in order to use the
desired feature.
The AMAX panel identifies keyfob users by device RFID. AMAX Keypad programming supports
entering RFID automatically for Radion devices.
4
When the keyfob RFID is asked for, press [*] for 3s to toggle between AUTO and
MANUAL mode.
When MANUAL is selected, enter the 9-digit RFID manually.
When AUTO is selected, trigger the RF device and the RFID is entered automatically.
RF Repeater
The AMAX panel identifies repeater devices by device RFID. AMAX Keypad programming
supports entering RFID automatically for Radion devices.
4
When the repeater RFID is asked for, press [*] for 3s to toggle between AUTO and
MANUAL mode.
When MANUAL is selected, enter the 9-digit RFID manually.
When AUTO is selected, trigger the RF device and the RFID is entered automatically.
RF Sensor Diagnose
6.7
6.7.1
6.7.2
AMAX panel
Settings | en
83
Bosch Sicherheitssysteme GmbH
Installation Manual
2015.05 | 06 | F.01U.309.277