![Bosch AMAX 4000 Installation Manual Download Page 28](http://html.mh-extra.com/html/bosch/amax-4000/amax-4000_installation-manual_39247028.webp)
–
Make sure that the grounding terminal is always connected and that N, L1 or
xx are
connected correctly.
–
Make sure to first disconnect the positive wire of the battery when removing it from the
system.
–
Be careful when connecting the positive (red) wire and the "BATT +" port of the system.
Make sure not to short-circuit with the "BATT +" port of the AMAX panel or the housing to
prevent electric arc from occurring.
!
Caution!
Battery
Damage or contamination of the system is possible if the battery is not handled correctly or if
the battery is not replaced on a regular basis.
–
Only use a non-spillable battery.
–
Place a label with the last replacement date on the battery.
–
Under normal conditions of use, replace the battery every 3-5 years.
–
Recycle the battery after replacement according to local regulations.
How to mount the battery
1.
Place the battery on the bottom of the enclosure.
2.
Position the red and black wires.
3.
Connect one end of the black wire to the "BATT -" port of the AMAX panel, and the other
end to the negative (-) pole of the battery.
4.
Connect one end of the red wire to the "BATT +" port of the AMAX panel, the other end to
the positive (+) pole of the battery.
P
Once the installation is complete, the AMAX panel will begin to charge the battery.
AMAX 2100 / 3000
AMAX 3000 BE / 4000
+
_
BATT
+
_
BATT
+
Battery
_
Figure 5.3: Connection of the battery for AMAX 2100 / 3000 and AMAX 3000 BE / 4000
System Power Up
1.
Power up the AMAX panel.
The language setting menu is displayed.
2.
Set the date and time. Otherwise, the system prompts as fault.
P
After the AMAX panel is powered up or reset, it resets to previous arming / disarming
status.
5.3
28
en | Installation
AMAX panel
2015.05 | 06 | F.01U.309.277
Installation Manual
Bosch Sicherheitssysteme GmbH