The output is reset when the system arming or disarming or the output time ends.
22 - RF Keyfob Button 3
If the output time of this output is set to 000, the keyfob button 3 works as a toggle:
This output is operated when the keyfob button 3 is pressed.
The output is reset when the keyfob button 3 is pressed again.
23 - RF Keyfob Button 4
If the output time of this output is set to 000, the keyfob button 4 works as a toggle:
This output is operated when keyfob button 4 is pressed.
The output is reset when the keyfob button 4 is pressed again.
24 - Chime Indication
This output is operated when a chime indication occurs.
25 - Verified Alarm
This output is operated when a verified alarm occurs.
26 - Unverified Alarm
This output is operated when an unverified alarm occurs.
27 - Technical Alarm
This output is operated when a technical alarm occurs.
28 - Bypassed Zone
This output is operated when a zone is bypassed.
29 - Ready to Arm
This output is operated when the system is in ready to arm state.
30 – Walk Test Output Mode
This output is operated when the system is in walk test mode.
31 – 24h Alarm
This output is operated when a 24h alarm occurs. This output works only a 24-hour zone.
The output is reset when the 24h alarm is reset or the output time ends.
32 – 24h Panic Alarm
This output is operated when a 24h panic alarm occurs. This output works only on zone type
10.
The output is reset when the 24h panic alarm is reset or the output time ends.
33 – Medical Alarm
This output is operated when a medical alarm occurs.
The output is reset when the medical alarm is reset or the output time ends.
34 – RF Power Fault
The output is operated in the following cases:
–
The battery of the RF transmitter is low.
AMAX panel