![Bosch AMAX 4000 Installation Manual Download Page 143](http://html.mh-extra.com/html/bosch/amax-4000/amax-4000_installation-manual_39247143.webp)
No response from the zone
for a short time after power
up
–
To ensure normal
operation, the system
should be left alone for a
minute after power up
–
Operate after 1 minute
AC power fault
–
AC power fuse is burnt.
–
Check if the 18V of the
transformer is correctly
wired and replace the
fuse
Over current protection of the
auxiliary power
–
Abnormal wiring of the
12V auxiliary power
–
The auxiliary power
exceeds the power
supply upper limit for the
AMAX panel
–
Reconnect the auxiliary
power
–
Use external power
supply for perimeter
devices
The auxiliary power cannot be
recovered after short circuit
–
AC power and battery
fail
–
Power up AC power and
battery again
Failure of battery is still
displayed after the battery is
replaced
–
The battery might be
tested 4 hours after the
system is armed each
time
–
The voltage of the
battery is lower than 12V
–
The fault will be
automatically cleared
when the system is reset
or the battery is re-
tested
–
Charge the new battery
for a period of time until
the voltage reaches 12V
or above
Not entering programming
mode after power up
–
The system is in alarm
state
–
The system is in arming
state
–
Reset the alarm
–
Disarm the system and
keep it in the disarming
status
The red LED on the main
board goes off
–
Abnormal AC power and
backup battery
–
The main board fails
–
Check AC power and
backup battery
–
Replace the main board
The system does not dial
when the alarm presents.
–
Relevant receiver
parameters are not set
–
Correctly set the
telephone number, set
transmission format to
CID and set zone alarm
to corresponding paths
Remote telephone arming fail –
The remote telephone
arming is disabled (the
address 0144 is set to 0)
–
There are multiple areas
in the system
–
Program the address
0144 to a number from 1
to 15
–
The telephone arming is
available when the
system has area 1 only
AMAX panel
Troubleshooting | en 143
Bosch Sicherheitssysteme GmbH
Installation Manual
2015.05 | 06 | F.01U.309.277