Instruction manual GLM-I
Totals
38.019.129.001 en
291
22
Tare total *2: Total 2 counts single packages
–
The tare total for total 2 is increased for each package by the tare weight of the pack-
age.
–
If printing total 2 or if the preset value for total 2 is reached, a prespecified total2 tare
is added to the tare total for total 2. Total2-tare, for example, corresponds to the box
weight.
Tare total *2 = (total of single tare) + (total2-tare)
Tare total *2: Total 2 counts to trigger total 1
–
The tare total for total 2 is increased for each package by the tare weight of the pack-
age.
–
When printing total 1 or when the preselection for total 1 is reached, total1-tare is add-
ed to the tare total for total 2. Total1-tare, for example, corresponds to the box weight.
–
When printing total 2 or when the preselection for total 2 is reached, total2-tare is add-
ed to the tare totalfor total 2. Total2-tare corresponds to the pallet weight for example.
When total 1 is triggered x n, the tare total *2 is established as follows:
Tare total *2 = (total of single tare) +n(tare) + (Total2-tare)
Example: Total1-tare. The procedure for total 2 and 3 is the same.
Mode level: 2
<Configure total> / <Total tare> / <Total 1 tare>
Enter value and confirm.
22.6
Select deletion criteria for totals
22.6.1
Select Totals deletion criteria for Total 1
This is where you can define whether and at what mode level Total 1 is deleted when trig-
gered. Alternatively, you can allow Total 1 to be deleted directly by triggering Total 2.
The following settings are possible:
<With delete>:
Total 1 is deleted with the next single weight after printing with
Total 1.
<Without in mode 1>:
–
Total 1 is
not
deleted after printing Total 1 in mode level 1.
–
Total 1 is not deleted after printing Total 1 in mode level 2.
<With *2 in mode 1>:
Total 1 can only be deleted by triggering Total 2. Total 1 is de-
leted with the next single weight after printing with Total 2.
Mode level: 5
Select total 1 deletion criteria
<Main menu> / <Totalization> / <Total del. criterion> / <Total 1>
Press softkey with respective setting.
Summary of Contents for GLM-I
Page 410: ...Interfaces Instruction manual GLM I 408 38 019 129 001 en 30 Illustration 76 Data transmission...
Page 484: ...Appendix Instruction manual GLM I 38 019 129 001 en Illustration 123 Example of list 9...
Page 486: ...Appendix Instruction manual GLM I 38 019 129 001 en Illustration 125 Example of list 14...
Page 488: ...Appendix Instruction manual GLM I 38 019 129 001 en Font set Western Europe ASCII 144 255...
Page 489: ...Instruction manual GLM I Appendix 38 019 129 001 en Font set Eastern Europe1 ASCII 144 255...
Page 490: ...Appendix Instruction manual GLM I 38 019 129 001 en Font set Eastern Europe2 ASCII 144 255...
Page 491: ...Instruction manual GLM I Appendix 38 019 129 001 en Font set Greek ASCII 144 255...
Page 492: ...Appendix Instruction manual GLM I 38 019 129 001 en Font set Cyrillic ASCII 144 255...