Error Codes
|
93
MicroFlo Select Microplate Dispenser
Error Name
Code Brief Description
BOOT_POWERUP_CHECKSUM_FAIL 1001
Bootcode powerup checksum test failed
BOOT_ERROR_UNKNOWN 1002
Unknown error in bootcode
BOOT_PAGE_PROGRAM_ERROR
1003 Bootcode page program error
BOOT_BLOCK_SIZE_ERR 1004
Bootcode
block size error (not 256)
BOOT_INVALID_SIGNATURE
1005 Invalid processor signature (not
1280,1281,2560,2561)
BOOT_MEMORY_EXCEEDED 1006
Bootcode memory exceeded
BOOT_INVALID_SLAVE_PORT
1007 Invalid slave port
BOOT_INVALID_SLAVE_RESPONSE 1008
Invalid response from slave
BOOT_INVALID_PROCESSOR
1009 Invalid processor detected
BOOT_DOWNLOAD_CHECKSUM_ERR
1010 Checksum error downloading basecode
PARAMETER_LIMIT_ERR
2400 Parameter limit exceeded
PROGRAM_LOCKED
4000 Program locked so operation denied
PROGRAM_NONERASABLE 4100
Program
non erasable so delete denied
SC_NAK_ERROR 8100
Communications
NAK
SC_TIMEOUT_ERROR 8101
Timeout
while waiting for serial message
data
SC_COM_BUSY_ERROR 8102
Instrument
busy and unable to process
message
SC_RX_BUF_OVERFLOW_ERROR 8103
Receive buffer overflow error
SC_CHECKSUM_ERROR 8104
Checksum
error
SC_INVALID_SCRUCT_TYPE 8105
Invalid
structure type in byMsgStructure
header field
SC_INVALID_DESTINATION 8106
Invalid
destination in byMsgDestination
header field
SC_OBJECT_NOT_SUPPORTED 8107
Request
object received not supported by
instrument
SC_MSG_BODY_SIZE_ERROR 8108
Message
Body size exceeds max limit
SC_MAX_REQS_RUNNING_ERROR 8109
Max
number of requests currently running
and cannot run the latest request
SC_NO_REQS_RUNNING_ERROR 810A
No
request running when response
request issued
SC_RESP_NOT_READY_ERROR 810C
Response for outstanding request not
ready yet
SC_INST_NOT_IN_PC_COMM_MODE 810D
Instrument not in a mode to receive a PC
message
SC_REQ_PARAMS_NOT_VALID 810E
One
or
more request parameters are not
valid
TCB_NOT_AVAIL_ERR
A000 Task control block not available
DEV_NOT_AVAIL_ERR A100
<device>
not
available
CODE_VERSION_ERR A200
Version
strings for multiple uProcessors
do not match
POWER_SUPPLY_ERR
A300 <test type> power supply level error
MALLOC_ERR A400
Malloc
failed
DISPLAY_IN_USE A500
Multiple
tasks attempted to use display
simultaneously
Summary of Contents for MicroFlo select
Page 1: ...Operator s Manual Dispenser MicroFlo Select ...
Page 2: ......
Page 44: ...26 Installation BioTek Instruments Inc ...
Page 74: ...56 Operation BioTek Instruments Inc ...
Page 116: ...98 Dispensing to Test Tubes BioTek Instruments Inc ...
Page 126: ...108 Gravimetric Calibration Instructions MicroFlo Select Microplate Dispenser ...