background image

 

 

Contents 

 

.INTRODUCTION .......................................................................................................................1 

. SAFETY NOTES........................................................................................................................1 

. PRECAUTIONS .........................................................................................................................2 

. MAINTENANCE .......................................................................................................................3 

. HOW DOES YOUR ATMOSPHERIC WATER GENERATOR WORK?..................................3 

. FEATURES OF ATMOSPHERIC WATER GENERATOR........................................................4 

. OPERATING YOUR ATMOSPHERIC WATER GENERATOR ...............................................7 

1. DIGITAL TOUCH SCREEN FUNCTION ...........................................................................8 

1.1. Screen Indication........................................................................................................8

 

1.2. Digital Touch Screen indication……………………………………………...…….10 

2. SETTING UP......................................................................................................................12 
3. OPERATIONAL STAGE....................................................................................................13 
4. CLEANING AND REPLACEMENT OF FILTERS...........................................................16 

4.1. Cleaning ...................................................................................................................18 
4.2. Sterilization ..............................................................................................................25 
4.3. Replacement.............................................................................................................27 

5. Attention..............................................................................................................................31 

. TROUBLE SHOOTING...........................................................................................................32

 

. TECHNICAL SPECIFICATIONS……………………………………………………….……36 

 

Note

We reserves the right to at any time without notice make any changes/amendments/deletions 

and/or variations to the contents of this manual.

 

Summary of Contents for HR-90HK

Page 1: ...UCH SCREEN FUNCTION 8 1 1 Screen Indication 8 1 2 Digital Touch Screen indication 10 2 SETTING UP 12 3 OPERATIONAL STAGE 13 4 CLEANING AND REPLACEMENT OF FILTERS 16 4 1 Cleaning 18 4 2 Sterilization 25 4 3 Replacement 27 5 Attention 31 Ⅷ TROUBLE SHOOTING 32 Ⅸ TECHNICAL SPECIFICATIONS 36 Note We reserves the right to at any time without notice make any changes amendments deletions and or variations...

Page 2: ...duo functional machine Ⅱ SAFETY NOTES 1 The socket should be equipped with reliable protection earthing 2 Do not remove earthing terminal from the power cord 3 Do not use extension plug nor extension adaptor 4 Always keep the unit from poisonous gas and liquid 5 Do not use damaged electrical plug or power cable 6 Unplug power cord before maintenance 7 Do not share the electrical socket with other ...

Page 3: ...rd Power supply When the unit operates below this level the unit becomes noisy with the possibility of overheating When this occurs immediately switch the unit off until the voltage returns to normal 6 Avoid prolonged direct eye exposure to ultraviolet device as it may damage the eye 7 Prevent children playing with HOT knob to avoid scalding 8 This unit is not suitable for use at places with spray...

Page 4: ...It is important to be aware that your Atmospheric Water Generator is a humidity and temperature driven machine This means the machine totally depends on the level of humidity in the air and the temperature to produce water Ideally the humidity level should be at least 50 or above to achieve the machine s optimum performance In places with lower humidity level the machine will still produce water b...

Page 5: ...ystem Ⅵ FEATURES OF ATMOSPHERIC WATER GENERATOR 1 Microcomputer The unit is fitted with a microcomputer which ensures proper working of internal parts The machine has preset hot cold temperature adjustable functions Temperature of hot or cold water can preset according to personal preference 2 Electronic Sensors Various electronic sensors are attached to parts such as UV light heating mechanism an...

Page 6: ...g to the ambient temperature and humidity through frequency conversion control system achieving the purpose of energy saving and noise reducing 7 Condensing coils The condenser is designed especially and with food class coating to prevent any metal pollution and improve water production efficiency 8 Multi Stage Filtration System Our dedication to providing high quality great tasting water to our c...

Page 7: ...body 8 4 1 Pre Carbon Filter Remove organic compounds odor free chlorine heavy metal etc 8 4 2 Post carbon filter Further remove any color odor heavy metal organic compound and chlorine at the same time protecting the RO membrane from chlorine and thus extend the life span on the RO membrane 8 4 3 RO membrane To remove micro impurity colloid heavy metal soluble solids bacteria and other harmful su...

Page 8: ...d clean and avoids second pollution 11 Overheat Protector Overheat protector offers further protection for your machine In case of overheat in hot pot during heating process this protector will automatically shut off heating device 12 Novel and Noble Body The attractive modern design together with digital touch screen makes the machine easy to operate and more options to select personal preference...

Page 9: ...ou start the machine By reading and following the simple manual you will familiarize yourself with your new water machine and all its functions ensuring yourself of a machine constantly operating at its optimum level 1 DIGITAL TOUCH SCREEN FUNCTION 1 1 Screen Indication ...

Page 10: ...rating stops If the icon blinks it means the water generating function has been shut off manually 1 1 5 Booster bump icon indicator The bump is working when the icon flashes 1 1 6 Humidity indicator Under normal operation it indicates humidity level During settings it indicates adjusting value 1 1 7 Top tank water level indicator The arrow indicates water level pointing at 1 means the tank is empt...

Page 11: ...ight indicator When icon light on means top tank UV light function normal light off means UV light not working Flashing means top tank UV not functioning normally Reflux UV light indicator When icon light on means reflux UV light on means UV light function normal light off means UV light not working Flashing means top tank UV not function normal Bottom tank UV light indicator When icon light on me...

Page 12: ...de icon to select function Select function needed to be adjust H ON OFF Indicate present heating function on or off press to make desire adjustment C ON OFF Indicate present cooling function on or off press to make desire adjustment W ON OFF Indicate present water generating function on or off press to make desire adjustment H 075 095 Shows the present hot water temperature soft press adjustment i...

Page 13: ...pout dispense icon Continuous soft pressing the icon until the icon flashing then press to dispense hot water 2 SETTING UP 2 1 Please confirm parts in the package are of complete set The unit should be placed on solid and level ground and be located in place with good air circulation The unit should be placed no less than 30 cm from the wall Push down the lever of braking wheel to get the machine ...

Page 14: ...to fill up all the tanks depends on weather condition 3 3 When the machine has enough water soft press the icon and then press to select options to adjust When heating is on the Hot in red color light will turn on light turns off when function is off This will happen when there is enough water and start heating It won t stop until the temperature reached the pre set level When close the heating fu...

Page 15: ... cleaning and maintenance menu After cleaning or replacement finish soft press key and re set number to zero T 000 soft press again and the icon will stop flashing Timer has been re set 3 8 When temperature drop to below normal machine will start defrost the Defrost icon will flash 3 9 For cool water dispensing keep pressing on the key For hot water dispensing press key until icon flashes to unloc...

Page 16: ...2 Brand new machine under first time use need to follow Machine cleaning and sterilizing procedure and remove odor from machine parts Optional parts Water tap Tee City water input Input Valve Water tubing Connector Filter Cup PPF Filter ...

Page 17: ...ctive carbon 3 6 months ammonia removal Pre carbon filter 3 6 months Post carbon filter 6 9 months RO membrane 15 24 months TCR carbon filter 6 9 months UV light bulb 12 months or upon UV fault warning Note 1 The above recommended service timing is for reference only 2 After a long period of service we recommend that you replace the filters to ensure that your unit will always produce the cleanest...

Page 18: ...ste Water Drain City Water Input Air filter Stainless Stell Bottom Tank Air exhaust Electric control center Leakage Detect Device LCD DTS screen Water tap Drip tray Wheel PPF or Zeolite active carbon TCR Carbon Filter Pre Carbon Filter RO Membrane Post Carbon Filter ...

Page 19: ...5 24 months PPForZeolite active carbon 9 12 months TCR active carbon 6 9 months UV light tube 12 months or replace when UV warning happens Attention Different countries or regions may have different environment the above replacement period is for reference only If the machine is continues operation for a long term filters and UV light tube inside the machine need to be replaced every once in a whi...

Page 20: ... from behind and side of the machine rinse in clean water to remove dirt and dust Install back to the machine when the filter is dry diagram 4 1 1 1 4 1 1 2 4 1 1 3 4 1 1 4 4 1 1 5 4 1 1 6 4 1 1 1 4 1 1 2 4 1 1 3 4 1 1 4 4 1 1 5 4 1 1 6 4 1 2 Cleaning of water collector Take out water collector from the back diagram 4 1 2 Clean and replace back to original position 4 1 2 water water ...

Page 21: ... 3 remove filter cup diagram4 1 3 4 Take out filter net and filter fibre diagram4 1 3 5 rinse the cup filter with clean water diagram4 1 3 6 Pull out the bottom tank level sensor PIN diagram4 1 3 7 PIN disconnect UV light connection pin diagram4 1 3 8 Disconnect the two tubes connecting to air pump diagram 4 1 3 9 pull out outlet tube from the bottom tank diagram 4 1 3 10 Unscrew UV light plastic ...

Page 22: ...ATMOSPHERIC WATER GENERATOR 21 4 1 3 1 4 1 3 2 4 1 3 3 4 1 3 4 4 1 3 5 4 1 3 6 4 1 3 7 4 1 3 8 4 1 3 9 4 1 3 10 4 1 3 11 4 1 3 12 A B ...

Page 23: ...e type of tubing and connect the outlet tubing of the post carbon filter to the inlet tubing of the TCR carbon filter diagram 4 1 4 4 4 1 4 1 4 1 4 2 4 1 4 3 4 1 4 4 Disconnect the TCR carbon filter outlet tubing diagram 4 1 4 5 Use a same tube material and connect the TCR carbon filter outlet tubing to a container diagram 4 1 4 6 Pull out bottom tank diagram 4 1 4 7 Remove the stainless steel mes...

Page 24: ...om tank 4 1 4 5 4 1 4 6 4 1 4 7 4 1 4 8 After cleaning follow the water circulating order reconnect and secure all tube connectors make sure to double check for any leakage diagram 4 1 4 11 Put back on front panel diagram 4 1 4 12 turn on machine begin cleaning the RO membrane by letting the machine run itself or fill up bottom tank with city water Soft touching the icon diagram 4 1 4 13 Then touc...

Page 25: ...ghtly salty To improve the taste drain out water from back of the machine a few times will improve signific antly When the machine is brand new the active carbon may still loosen some carbon powder may get into the top tank but it will not affect the machine s performance If this happened drain out water from hot water outlet from back of the machine diagram 4 1 4 16 and clean top tank with cloth ...

Page 26: ...he machine enter stand by condition diagram 4 2 1 Open the top cover diagram 4 2 2 and then open the top tank cover diagram 4 2 3 Mix sterilization solution according to ratio and pour into the top tank diagram 4 2 4 Check to make sure tank cover closed properly and tight 4 2 3 Soft touch the icon to turn on machine touch the icon then touch to unlock then touch the icon to dispense about one lite...

Page 27: ...the unit and have it running automatically till top tank is full of water 4 2 6 Touch the icon and then continue touching icon to unlock then touch the icon to dispense about 2L of water Shut down the unit Drain off all remaining water from hot water drain outlet at the back diagram 4 2 8 4 2 7 Repeat the above steps in 5 and 6 in order to clean off the remaining solution in top tank Suggest twice...

Page 28: ...1 2 To replace the pre carbon post carbon and TCR carbon filters pull out inlet tube on both ends diagram 4 3 1 3 4 3 1 4 unplug fast snap connector and connect onto the new filters Replace RO membrane pull out pure water outlet tube diagram 4 3 1 5 then pull out waste water outlet tube diagram 4 3 1 6 and RO membrane inlet water tube diagram 4 3 1 7 take down fast connector and plug back onto the...

Page 29: ... time the UV light may break There will be a warning beep sound and UV icon will flash the UV light has to be replaced Before replacing soft touching the icon until the machine enter stand by condition diagram 4 3 2 1 and unplug power cord Open top cover diagram 4 3 2 2 Remove screws on top end diagram 4 3 2 3 Disconnect UV connection pin diagram 4 3 2 4 Pull out UV bulb diagram 4 3 2 5 Replace wi...

Page 30: ...touching the icon until the machine enter stand by condition diagram 4 3 3 1 and unplug power cord Open top cover diagram 4 3 3 2 Remove foam cup of UV diagram4 3 3 3 Remove black insulation cover diagram 4 3 3 4 Disconnect UV connection pin diagram 4 3 3 5 Pull out UV bulb diagram 4 3 3 6 Replace with new bulb and replace back all parts ...

Page 31: ... to cool off Pull out bottom tank diagram 4 3 4 2 Pull out bottom tank UV light connection pin diagram4 3 4 3 Unscrew UV light assembly plastic daigram 4 3 4 4 and take out UV light daigram 4 3 4 5 Replace new UV light glass tube diagram 4 3 4 6 Apply silicon between the UV light cords and assembly daigram 4 3 4 7 Wait until the silicon dry up and screw back on the plastic screw plate diagram 4 3 ...

Page 32: ... 93 for more than 30 minutes once a week Continue soft pressing the icon until the faucet is unlock then press icon to release 500 ml of hot water from faucet 5 3 If the machine was not in use for 2 to 5 days please drain out 500ml of cool water before dispensing for drinking use If the machine is to be inactive for more than 5 days it is recommended to drain off water in all tanks and switch off ...

Page 33: ... before drain out water from the back outlets Must soft press the icon until machine enter stand by condition then drain water out from the machine Ⅷ TROUBLE SHOOTING Problem One The UV warning icon blinks with three short beeps Solution Check the ultraviolet device in top tank to make sure the bulb is lit and all wirings are correct If the UV is not working replace with new bulb by following step...

Page 34: ...m Five The indicator on screen display is blinking with beeping Solution After a long period of operation the filter might be over dirty and will be replaced Replace with a new filter by following steps in CLEANING STERILIZATION REPLACEMENT Reset the filtration warning time by following the 7th step in section OPERATIONAL STAGE Problem Six The system detected water leakage on base The red logo on ...

Page 35: ...e back outlets when cleaning top tank and hot tank Solutions Check water stopper inside water drain outlet is removed Problem Eight There is burning smell from the machine and meanwhile hot temperature indication has exceeded the preset Solutions Immediately touch the icon until the machine enter stand by condition unplug power cord from electrical outlet Stop draining immediately if you are on dr...

Page 36: ...vels The cooling function will be activated only when top tank water level on screen is above three levels Problem Eleven The machine makes water at a slow rate even after prolonged period of operation Solutions Make sure the temperature level is in appropriate range Check the humidity level in the room Low humidity level results in less water production Make sure that the hot cold water spouts ar...

Page 37: ...sensor is not blocked covered or too close to the wall Problem Thirteen The machine is with excessive vibration or noise Solutions Make sure there is no object placed on top of the machine Make sure that there is no water cup placed on water tray Open the front bottom panel and check if the copper tube at the side is touching the side panel Correct the position of copper tube slightly and slowly i...

Page 38: ...aration and void all warranty TECHNICAL SPECIFICATIONS Ⅸ Dimensions Height 112cm Width 45cm Depth 43cm Net Weight 49kg Power Voltage a c 220 240V 50Hz a c 220 240V 60Hz a c 100 120V 50Hz a c 100 120V 60Hz Power input 800 950W 800 950W Heating Wattage 500W 500W Cooling Power 380W 380W ...

Page 39: ... Quality Working Temperature 15 40 Temperature of Hot Water 75 95 Working Humidity 35 95 Temperature of Cold Water 4 10 Water Storage Capacity 12 5 Liters Atmospheric Water Production Capacity 30 40 50 60 70 80 90 0 10 15 20 30 25 制 水 量 升 ...

Page 40: ...ATMOSPHERIC WATER GENERATOR 39 Humidity 35 40 50 60 70 80 90 Capacity liter 10 14 18 5 22 25 28 30 Note The figure above only apply to model with heating function ...

Reviews: