
CFX96 and CFX384 Systems Manual
iii
Safety and Regulatory Compliance
For safe operation of the CFX96 system or the CFX384 system, we strongly recommend that you follow
the safety specifications listed in this section and throughout this manual.
Safety Warning Labels
Warning labels posted on the instrument and in this manual warn you about sources of injury or harm.
Refer to Table 3 to review the meaning of each safety warning label.
Instrument Safety Warnings
The warning labels shown in Table 4 also display on the instrument, and refer directly to the safe use of
the CFX96 system or the CFX384 system.
NOTE: For information about the C1000™ thermal cycler, refer to the C1000 thermal cycler
instruction manual.
Table 3. Meaning of safety warning labels
CAUTION: Risk of danger!
This symbol identifies components that pose a risk of personal
injury or damage to the instrument if improperly handled. Wherever this symbol appears,
consult the manual for further information before proceeding
CAUTION: Hot surface!
This symbol identifies components that pose a risk of personal
injury due to excessive heat if improperly handled
Table 4. Instrument Safety Warning Labels
Icon
Meaning
Warning about risk of harm to body or equipment
.
Operating the CFX96 or CFX384 real-time PCR detection system before reading this
manual can constitute a personal injury hazard. For safe use, do not operate this instrument
in any manner unspecified in this manual. Only qualified laboratory personnel trained in the
safe use of electrical equipment should operate this instrument. Always handle all
components of the system with care, and with clean, dry hands
Warning about risk of burning.
A thermal cycler generates enough heat to cause serious burns. Wear safety goggles or
other eye protection at all times during operation. Always allow the sample block to return
to idle temperature before opening the lid and removing samples. Always allow maximum
clearance to avoid accidental skin burns
Warning about risk of explosion
.
The sample blocks can become hot enough during the course of normal operation to cause
liquids to boil and explode
Summary of Contents for CFX384
Page 9: ...Table of Contents viii ...
Page 49: ...Protocols 40 ...
Page 89: ...Data Analysis Overview 80 ...
Page 149: ...Resources 140 ...
Page 157: ...Index 148 ...